Hard start after #100
I ground my stock plate to a 100 the first couple days it was fine. But the day after I done it i lost my fuel cap and the new one didn't vent right.. I started it after a few hrs of sitting one night to let it warm up. it didn't start easy then after a couple min it died. long story short the suction pulled the fuel backwards and I had to re prime the system. now to get it to start now I have to depress the pedal slightly and let it run @ 1000 rpms for a bit then I can let off and it will run fine. If I dont it will not start, and if i don't hold the pedal it will run rough and die. but after a few seconds of run time it will smoth up... i'm going to put a temporary fuel guage on the fuel filter tomorrow to check the pressure. I talked to a mech that deals only with dodge cummins, and he said something about a shaft that may be wore just i bit and have a "sweet spot" in it. He said no big dill just depress the pedal on start up and it will eventually clear it's self up. I wondered if there's a check valve somewhere i may have screwed up with the venting problem.
So I need to move my plate back? It doesn't have very much adjustment to it.. when I had it off it didn't have much more than a 1/4" slot.. but i'll move it back and see what i got.. Thanks for your help!
When adjusting a fuel plate moving it a little make a lot of difference.
Also, what is your base pump idle at? Should be around 750-800 rpm in gear. Bumping it a little might help with your starting issue.
Also, what is your base pump idle at? Should be around 750-800 rpm in gear. Bumping it a little might help with your starting issue.
Sounds like air in the system. That suction problem may have caused a rupture in the fuel lines or the diaphram in the fuel lift pump. Have you replaced the fuel lines to the engine recently?
Thread
Thread Starter
Forum
Replies
Last Post
Blanton
Diesel In Distress - Support Ticket
2
Apr 15, 2015 06:29 PM