05 6.0 no start when hot
Joined: Mar 2007
Posts: 1,748
Likes: 107
From: Ash Flat Arkansas
came in with a no start when hot condition...full of oil...good oil pressure...low icp pressure...removed both valve covers and inspected all injector orings found no problems...replaced connecting tubes...no change...replaced ipr...no change...replaced hpop...no change...starts just fine cold and runs fine once it starts but still will not start hot...now what???
Joined: Mar 2007
Posts: 1,748
Likes: 107
From: Ash Flat Arkansas
it runs perfect once it starts...no miss at all...so i really dont think it is an injector problem...i'm starting to think that maybe it is a cracked branch tube or something
Joined: Mar 2007
Posts: 1,748
Likes: 107
From: Ash Flat Arkansas
yeah that's what its doin and we've checked the injector orings put new connecting tubes in and a new hpop with the new fitting and its still loosing hpop pressure after the engine warms up
You said ICP was low, did you change the ICP sensor?
I agree, sounds like a high pressure oil leak. Snap to connect fitting is the most common on these. It's not if, but when it fails kind of deal. Just search for it, pretty common.
I agree, sounds like a high pressure oil leak. Snap to connect fitting is the most common on these. It's not if, but when it fails kind of deal. Just search for it, pretty common.
Thread
Thread Starter
Forum
Replies
Last Post
Cavnar
Diesel In Distress - Support Ticket
3
Sep 9, 2015 07:18 PM
Accubuck
Diesel In Distress - Support Ticket
5
May 7, 2015 04:46 PM
cjgregory
Diesel In Distress - Support Ticket
0
Mar 31, 2015 01:45 PM
dandbmcc
Ford Powerstroke 03-07 6.0L
5
Mar 14, 2015 11:05 PM
thumperf350
Ford Powerstroke 03-07 6.0L
4
Jan 8, 2015 12:55 AM