Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

cummins broke down

Thread Tools
 
Search this Thread
 
  #1  
Old 12-20-2011, 11:56 AM
mcneel102's Avatar
Newbie
Thread Starter
Join Date: Oct 2011
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Default cummins broke down

i have a 2000 dodge 2500 that i was driving and it shut down like it was outta diesel i pulled the fuel line off my air dog bumped the key diesel poured out like it should i took off #1 injector line bumped it again diesel was coming out and put it back on but still didnt start then sprayed starting fluid in the air intake and it tried to start but it didnt so i have no clue what it could be so if anyone could help me out please do
thanks connor
 
  #2  
Old 12-20-2011, 12:07 PM
MillerBoyzDiesel's Avatar
Diesel Wrench
Join Date: Dec 2011
Location: Kentucky
Posts: 763
Received 39 Likes on 37 Posts
Default

you got fog lights on that truck?
 
  #3  
Old 12-20-2011, 12:39 PM
NadirPoint's Avatar
Diesel Bomber
Join Date: Aug 2009
Location: CO
Posts: 2,257
Received 186 Likes on 159 Posts
Default

VP44 died?
 
  #4  
Old 12-20-2011, 12:42 PM
mcneel102's Avatar
Newbie
Thread Starter
Join Date: Oct 2011
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Default

No I don't have fog lights? And also I have no clue how to know if the vp died
 
  #5  
Old 12-20-2011, 12:48 PM
MillerBoyzDiesel's Avatar
Diesel Wrench
Join Date: Dec 2011
Location: Kentucky
Posts: 763
Received 39 Likes on 37 Posts
Default

well see if you can find another relay to swap out with the fuel sys. relay in your underhod fuse box. then crack your injector lines and see what happens. Usually I use the fog lamp relay for the swap, should be another one under there you can use
 

Last edited by MillerBoyzDiesel; 12-20-2011 at 12:50 PM. Reason: info.
  #6  
Old 12-21-2011, 08:50 AM
NadirPoint's Avatar
Diesel Bomber
Join Date: Aug 2009
Location: CO
Posts: 2,257
Received 186 Likes on 159 Posts
Default

Originally Posted by mcneel102
I have no clue how to know if the vp died
That's just what it sounds like to me. Pulling codes will tell the story.
 
  #7  
Old 12-21-2011, 08:04 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

pull codes - 3 key cycles

p0216 code - need new vp44

no codes - check fuel pressure from lift pump

no pressure - check relay

good relay - change lift pump

low pressure - change filter bleed all 6 lines

new filter low pressure - change lift pump bleed all 6 lines

if you only get fuel out of 3 lines - new vp44 likly

if it still dosnt start then your probably going to need a new vp44
 
  #8  
Old 12-21-2011, 10:48 PM
1993firstgennewbie's Avatar
Diesel Wrench
Join Date: Mar 2010
Location: denver colorado
Posts: 785
Received 43 Likes on 33 Posts
Default

get a 12 valve
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Shun70
Diesel Engine Conversions
0
09-21-2015 01:39 AM
Diesel Bombers
General Diesel Related
0
10-31-2014 08:10 AM
Diesel Bombers
General Diesel Related
0
10-24-2014 04:40 AM
Omingnome
Diesel In Distress - Support Ticket
5
10-20-2014 12:25 PM
Diesel Bombers
General Diesel Related
0
10-20-2014 08:10 AM



Quick Reply: cummins broke down