12 Valve 2nd Gen Dodge Cummins 94-98 Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with P7100 Injection Pumps

Starting issue

Thread Tools
 
Search this Thread
 
Old Dec 12, 2012 | 04:58 PM
  #1  
cummincider's Avatar
Thread Starter
|
Diesel Fan
Joined: Oct 2012
Posts: 79
Likes: 0
Default Starting issue

I just bought a new battery and had 4 k gsk put in truck was running great quick start everything great it sat for 6 days cause I had to work and tried starting it grid heater warmed up fine then I try to turn over I just get one solid click then nothing any help would be great thanks
 
Reply
Old Dec 12, 2012 | 05:22 PM
  #2  
H.R.D's Avatar
Super Moderator
iTrader: (3)
Joined: Dec 2010
Posts: 3,765
Likes: 1,052
From: Las Cruces, NM
Default

Batteries still charged? Try jumping it or putting a charger on them?
 
Reply
Old Dec 12, 2012 | 05:50 PM
  #3  
cummincider's Avatar
Thread Starter
|
Diesel Fan
Joined: Oct 2012
Posts: 79
Likes: 0
Default

Yep there juicy first thing I tried possible it's grounded some were or that my starter just said few outta no were

---AutoMerged DoublePost---

I just double checked the batteries and there full charged

---AutoMerged DoublePost---

Think it's just time for a new starter any way to check thanks
 

Last edited by cummincider; Dec 12, 2012 at 05:50 PM. Reason: Automerged Doublepost
Reply
Old Dec 12, 2012 | 09:07 PM
  #4  
daveO's Avatar
Diesel Bomber
Joined: May 2009
Posts: 1,030
Likes: 171
From: Pottstown, PA
Default

Try giving the starter a couple taps with a hammer.
 
Reply
Old Dec 13, 2012 | 04:13 PM
  #5  
cummincider's Avatar
Thread Starter
|
Diesel Fan
Joined: Oct 2012
Posts: 79
Likes: 0
Default

I beat the hell outta it just that one click then nothing I was told to check tot see if I got power going to it would I just take a volt meter and put one on the positive wire under the starter and ground the other to the block again all replays appreciated
 
Reply
Old Dec 13, 2012 | 06:51 PM
  #6  
geddy's uncle's Avatar
Diesel Enthusiast
Joined: Sep 2010
Posts: 415
Likes: 16
From: Keller, TX
Default

Originally Posted by cummincider
I beat the hell outta it just that one click then nothing I was told to check tot see if I got power going to it would I just take a volt meter and put one on the positive wire under the starter and ground the other to the block again all replays appreciated
Might just be the starter solenoid contacts all burned up. The starters themselves are pretty beefy, but, the OEM solenoid contacts are kind of smallish for carrying the sudden burst of current needed for kicking the Killer B into life. google up "Larry B's starter contacts". I've had a set in for probably 8 years, before the starter itself suffered a broken mount and had to be replaced. I installed new contacts on that one before the install, and have had no problems.
 
Reply
Old Dec 14, 2012 | 04:11 PM
  #7  
cummincider's Avatar
Thread Starter
|
Diesel Fan
Joined: Oct 2012
Posts: 79
Likes: 0
Default

Yea I had seen that on another post does anyone have the fuse box diagram mines Mia and idk what fuse is the starters
 
Reply
Old Dec 16, 2012 | 06:02 PM
  #8  
gyayo2012's Avatar
Diesel Enthusiast
Joined: Nov 2011
Posts: 242
Likes: 9
From: mA$$HOLE
Default

try your batery cables mine seem to do that everyonce in a while they get loose.. try cleaning them and tightening them again... mostly happens to my ground on driver side..
 
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
dskewes14
12 Valve 2nd Gen Dodge Cummins 94-98
2
Sep 14, 2015 09:19 AM
06kyleP
Ford Powerstroke 03-07 6.0L
2
Jul 19, 2015 06:10 AM
Squirt
Diesel In Distress - Support Ticket
0
Jun 19, 2015 12:40 PM
custom7.3
Ford 83-94 6.9 and 7.3L General
3
Nov 24, 2014 05:16 PM
7.3stroke
General Diesel Related
0
Oct 27, 2014 06:25 PM




All times are GMT -5. The time now is 04:13 PM.