Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

truck overheated now it wont run.

Old May 25, 2010 | 02:08 PM
  #1  
Silverline Concrete's Avatar
Thread Starter
|
Newbie
Joined: Jan 2010
Posts: 6
Likes: 0
Default truck overheated now it wont run.

i have a 99 7.3 6 speed powerstroke. i bought the truck and on the way home (3 hour ride) the engine overheated. i releaved the pressure from the resivor cap and let it cool down. i started it back up about 30 mins later and continued down the highway (had a 9' plow on the truck.) the temp guage got into the red again and it stalled out.

i got it towed and i went the nextt day with a bunch of coolant and tried to get the truck to run. i filled the resivor and i tried a shot of ether. it ran for a second and shut off. any ideas? it will just crank and not run. the fual pump is working.

thanks!
 
Old May 25, 2010 | 02:42 PM
  #2  
theSLEEPER's Avatar
Diesel Enthusiast
Joined: May 2010
Posts: 231
Likes: 7
From: Bay St. Louis, MS
Default

I think you probably have some type of issue before the truck ever overheated... How often do PSD's overheat?? Not often... Any codes?
 
Old May 25, 2010 | 03:14 PM
  #3  
ArizonaRedneck's Avatar
BOMBARDIER
Joined: Oct 2009
Posts: 4,366
Likes: 240
From: arizona
Default

is there any safety shutdowns or codes that have to be reset before it will start again
 
Old May 25, 2010 | 04:12 PM
  #4  
theSLEEPER's Avatar
Diesel Enthusiast
Joined: May 2010
Posts: 231
Likes: 7
From: Bay St. Louis, MS
Default

I don't think so... I would start by doing everything you can to verify the ability to run. Are you getting a "wait to start" light??
 
Old May 25, 2010 | 04:33 PM
  #5  
Silverline Concrete's Avatar
Thread Starter
|
Newbie
Joined: Jan 2010
Posts: 6
Likes: 0
Default give it a try.

i checked all the fuses. and there is a fuel pump shut-off switch that i checked. i checked the codes. and i accidently cleared them. (i have a crappy code reader) the only one that wouldnt clear is a Wastegate code (which shouldnt matter to the situation) and a camshaft position sensor error
 
Old May 27, 2010 | 11:23 PM
  #6  
wyoranch's Avatar
Diesel Wrench
Joined: Mar 2007
Posts: 551
Likes: 11
From: Stockdale, Tx.
Default

Cam position sensors are a big problem with the powerstrokes. They will crank and maybe start for a minute but then die. Sounds like two seperate issues happened to hit at the same time. My moneys on the cam position sensor
 
Old May 28, 2010 | 07:45 AM
  #7  
theSLEEPER's Avatar
Diesel Enthusiast
Joined: May 2010
Posts: 231
Likes: 7
From: Bay St. Louis, MS
Default

Good idea. CPS is the first thing I would change.
 
Old May 28, 2010 | 02:28 PM
  #8  
Silverline Concrete's Avatar
Thread Starter
|
Newbie
Joined: Jan 2010
Posts: 6
Likes: 0
Default

ha! you guys are good.

I was told by one of my local buddies that its either my CPS or IDM i replaced the CPS and it was all covered in coolant. thanks for the help! trucks started right up!
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
vin_diesel
Alternative Fuels , Additives , Fluids
1
Mar 1, 2016 01:43 PM
doublehbar
24 Valve 2nd Gen Dodge Cummins 98.5-02
13
Aug 9, 2015 12:35 AM
clarthom
Diesel In Distress - Support Ticket
8
Mar 5, 2015 07:27 PM
mountainmover
Big Rigs & Semis
0
Mar 1, 2015 06:03 AM
Diesel Bombers
Latest Automotive Industry News
0
Oct 14, 2014 08:40 AM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 01:24 AM.