Chevy/GMC 6.2L and 6.5L Discussion of Chevy and GMC Trucks with 6.2L and 6.5L Diesel Engines

Injector Pump timing

Old Oct 27, 2012 | 09:43 AM
  #11  
racer55's Avatar
Diesel Bomber
Joined: Oct 2012
Posts: 1,848
Likes: 103
From: Scugog Island ONT.
Default

You need to do a compression test to check cam timing and prove that you have good cylinder compression.

Next if that is good is to look at the drive gear on the IP,you can do this by removing the oil fill tube.
The IP drive flange has 3 bolt holes and 1 dowel pin,the drive gear has 3 round holes and 1 slotted hole-the dowel pin must be in the slotted hole.
 
Reply
Old Oct 27, 2012 | 09:51 AM
  #12  
daddywalt's Avatar
Thread Starter
|
Diesel Fan
Joined: Mar 2012
Posts: 37
Likes: 0
From: Homosassa
Default

I don't have a way of preforming a compression test. I will remove the oil fill tube next, will i need to drain the oil first? So once fill tube is off what am I looking for just that dowel pin is in slotted hole? Thank you so much for the fast reply!
 
Reply
Old Oct 27, 2012 | 09:59 AM
  #13  
racer55's Avatar
Diesel Bomber
Joined: Oct 2012
Posts: 1,848
Likes: 103
From: Scugog Island ONT.
Default

Yes pull the fill tube off the frt of the timing cover(no you won't need to drain the oil) and verify that the dowel is in the slotted hole.

harbor freight sells compression testers very cheap,they connect at the glow plug holes.
All glow plugs need to be removed for compression testing to give the starter a chance.
400psi minimum is considered acceptable.
Be sure to unplug the PMD before doing a compression test-you don't need fuel in those cylinders then.Remember to plug it back in later though.
 

Last edited by racer55; Oct 27, 2012 at 10:01 AM.
Reply
Old Oct 27, 2012 | 06:59 PM
  #14  
daddywalt's Avatar
Thread Starter
|
Diesel Fan
Joined: Mar 2012
Posts: 37
Likes: 0
From: Homosassa
Default

Ah something I mentioned but didn't bring up again, this truck has a DS2 IP so it is mechanical, no PMD. That adds ALOT more variables to the equation I know but I don't have the time or money to switch it back over to an electric IP. I have to work tomorrow so I won't be able to get to it until Tuesday at the earliest.

---AutoMerged DoublePost---

Also another late thought to add to our pondering minds; no smoke when I crank the motor. Confirmed fuel, and glow but no smoke.
 

Last edited by daddywalt; Oct 27, 2012 at 06:59 PM. Reason: Automerged Doublepost
Reply
Old Oct 28, 2012 | 09:04 AM
  #15  
racer55's Avatar
Diesel Bomber
Joined: Oct 2012
Posts: 1,848
Likes: 103
From: Scugog Island ONT.
Default

I mentioned the PMD as a way to shut off the fuel only.
 
Reply
Old Oct 30, 2012 | 01:20 PM
  #16  
daddywalt's Avatar
Thread Starter
|
Diesel Fan
Joined: Mar 2012
Posts: 37
Likes: 0
From: Homosassa
Default

Okay oil fill neck is off...kinda going by braille...stopping for lunch
 
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
quiksilver1j
1st Generation Dodge Cummins 89-93
1
Jul 30, 2015 12:41 PM
Stox5225
12 Valve 2nd Gen Dodge Cummins 94-98
22
May 14, 2015 05:17 PM
SMatyac
12 Valve 2nd Gen Dodge Cummins 94-98
2
Nov 15, 2014 07:35 PM
91 7three
Ford 83-94 6.9 and 7.3L General
1
Nov 14, 2014 10:37 PM
jjbced
Chevy/GMC 6.2L and 6.5L
5
Oct 26, 2014 09:09 PM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 09:12 PM.