24 Valve 2nd Gen Dodge Cummins 98.5-02 Discussion of 24 Valve 5.9 Liter Dodge Cummins Diesels with VP44 Injection Pumps
Sponsored by Trailer Plus

ac fan

Old Apr 24, 2012 | 12:17 PM
  #1  
stevescummins's Avatar
Thread Starter
|
Diesel Fan
Joined: Mar 2009
Posts: 45
Likes: 0
From: Florida
Default ac fan

Hey Guys,
I was coming home yesterday and I smelled what smelled like wires burning. It lasted a couple minutes and quit. A little later I turned the fan up and got nothing until I turned it to full speed. All the lower setting quit. My fan has been squealing for a couple weeks. I pulled the controls and all the wiring looks good. The blower motor fuse is fine. I know I need to change the blower motor. How hard is that? And what else do you think would be bad? Would it be the resistor on the fan control? It is going to get hot again here in Florida at the end of the week. I need that ac fan working.
Any help would be appreciated.
 
Reply
Old Apr 24, 2012 | 12:41 PM
  #2  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

Blower motor is very easy to change, 3 or 4 screws and one wire connector. The cause of only having Full speed is the resistor pack being failed. It is close to the blower motor, 2 screws hold it in, and about 5 wires going into it. When I bought my truck I had the same issue, only full speed. I was able to repair mine as just a solder broke free, and it's been working for 3 years now.
 
Reply
Old Apr 24, 2012 | 02:23 PM
  #3  
stevescummins's Avatar
Thread Starter
|
Diesel Fan
Joined: Mar 2009
Posts: 45
Likes: 0
From: Florida
Default

Thanks for the help. I guess I know what I will be doing tomorrow.
 
Reply
Old Apr 26, 2012 | 08:23 AM
  #4  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

How did it go? Were you able to check it out?
 
Reply
Old Apr 26, 2012 | 09:00 AM
  #5  
lobsterman04's Avatar
Diesel Enthusiast
Joined: Apr 2009
Posts: 138
Likes: 6
From: Dyess AFB, TX
Default

If the fan only works on high...blower motor resistor. $20+ at stealership.
 
Reply
Old Apr 26, 2012 | 11:23 AM
  #6  
1AMatt's Avatar
Site Sponsor - 1aauto
Joined: Oct 2010
Posts: 1,514
Likes: 68
From: Pepperell, MA
Default

X2 on the resistor
 
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
black99
12 Valve 2nd Gen Dodge Cummins 94-98
0
Aug 20, 2015 11:40 AM
Dieseltech0593
12 Valve 2nd Gen Dodge Cummins 94-98
5
Jun 24, 2015 10:52 AM
Dieseltech0593
Diesel In Distress - Support Ticket
0
May 7, 2015 08:10 PM
Rbear
Diesel In Distress - Support Ticket
1
May 3, 2015 07:47 PM
es772
24 Valve 2nd Gen Dodge Cummins 98.5-02
1
Oct 23, 2014 08:29 AM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 08:44 AM.