24 Valve 2nd Gen Dodge Cummins 98.5-02 Discussion of 24 Valve 5.9 Liter Dodge Cummins Diesels with VP44 Injection Pumps
Sponsored by Trailer Plus

converter will not lock up normally

Old Apr 14, 2012 | 11:15 PM
  #1  
dieseldude848's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2010
Posts: 254
Likes: 6
From: Derry, N.H
Default converter will not lock up normally

hey guys, the owner before me wired in one of those converter lock up switches, and i just realized that it will not lock the converter unless i flick the switch. so does wiring in a manual switch to command lock up get rid of it locking up normally when the computer tells it to?
 
Reply
Old Apr 14, 2012 | 11:32 PM
  #2  
globalwarmingcontributor's Avatar
Diesel Enthusiast
Joined: Nov 2011
Posts: 194
Likes: 12
From: Illinois
Default

no... something is wrong with the wiring.... go through the wires... i hope your converter isnt all jacked up
 
Reply
Old Apr 15, 2012 | 12:27 PM
  #3  
dieseldude848's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2010
Posts: 254
Likes: 6
From: Derry, N.H
Default

do you mean check the wiring of the switch?
 
Reply
Old Apr 15, 2012 | 10:23 PM
  #4  
globalwarmingcontributor's Avatar
Diesel Enthusiast
Joined: Nov 2011
Posts: 194
Likes: 12
From: Illinois
Default

Yes
 
Reply
Old Apr 24, 2012 | 06:07 PM
  #5  
dieseldude848's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2010
Posts: 254
Likes: 6
From: Derry, N.H
Default

ok so i checked all the wiring, and it was correct except for the jumper lead thats put in place of the trans relay. i put it in the correct spot, and gave it a test run still no lockup unless i flick the switch. and sorry for the week late reply, starter solenoid took a crap, and was waiting on a new one to come in.
 
Reply
Old Apr 24, 2012 | 07:55 PM
  #6  
empty wallet's Avatar
Diesel Wrench
Joined: Jun 2011
Posts: 667
Likes: 118
From: New England
Default

did they cut the wire or did they use a scotchlok type splice connector? for whatever reason, cannot cut that wire to splice the switch in... according to suncoast. how was the jumper wrong?
 
Reply
Old Apr 24, 2012 | 11:19 PM
  #7  
dieseldude848's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2010
Posts: 254
Likes: 6
From: Derry, N.H
Default

if you look at the link, the jumper was in the middle vertical line going to the bottom horizontal line. when i swaped it, it made no difference, and no the wire is T-tapped not cut.
http://www.tstproducts.com/Torque%20...p%20Switch.pdf
 
Reply
Old Apr 27, 2012 | 03:47 PM
  #8  
dieseldude848's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2010
Posts: 254
Likes: 6
From: Derry, N.H
Default

any ideas is to why it wont engage by its self?
 
Reply
Old Apr 27, 2012 | 07:11 PM
  #9  
Russ Roth's Avatar
Diesel Enthusiast
Joined: Jul 2009
Posts: 133
Likes: 11
From: Vancouver, WA
Default

Originally Posted by empty wallet
did they cut the wire or did they use a scotchlok type splice connector? for whatever reason, cannot cut that wire to splice the switch in... according to suncoast.

I cut my wire and it has worked just fine about 4 years now. Those scotch locks are junk IMHO.
 
Reply
Old Apr 30, 2012 | 07:45 PM
  #10  
dieseldude848's Avatar
Thread Starter
|
Diesel Enthusiast
Joined: Dec 2010
Posts: 254
Likes: 6
From: Derry, N.H
Default

bump
 
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
cumminspwr11
12 Valve 2nd Gen Dodge Cummins 94-98
12
Oct 17, 2021 03:50 AM
Wizbangdoodle
Ford Powerstroke 08-10 6.4L
0
Sep 26, 2015 02:47 PM
Cody Cain
24 Valve 2nd Gen Dodge Cummins 98.5-02
0
Dec 22, 2014 01:27 PM
Cody Cain
Diesel In Distress - Support Ticket
0
Dec 21, 2014 06:50 PM
Jgloveracob
For Sale
0
Dec 7, 2014 10:47 AM


Thread Tools
Search this Thread