Ford Powerstroke 03-07 6.0L Discussion of 6.0 Liter Ford Powerstroke Turbo Diesels

oil cooler rebuild

Thread Tools
 
Search this Thread
 
  #1  
Old 10-20-2010, 01:48 PM
rickey1172's Avatar
Diesel Fan
Thread Starter
Join Date: Oct 2009
Location: greenville sc
Posts: 99
Received 5 Likes on 5 Posts
Default oil cooler rebuild

im getting ready to rebuild my oil cooler and do an egr delete. any tips or advice for some one doing their first one. thanks
 
  #2  
Old 10-20-2010, 02:04 PM
Mdub707's Avatar
BOMBARDIER
Join Date: Oct 2007
Posts: 8,208
Received 630 Likes on 510 Posts
Default

Make sure you have plenty of beer before you tear into it. Have fun, take your time and try not to get too frustrated.
 
  #3  
Old 10-20-2010, 06:44 PM
Jagsdiesel's Avatar
Diesel Bombers Sponsor- Jags Diesel
Join Date: Oct 2010
Location: Zimmerman, Mn
Posts: 175
Received 12 Likes on 12 Posts
Default

Its not bad. Just make sure to lube the o-ring on the new oil cooler before you put it into the housing. Hate to rip a seal and have to do it all over again.
Get a new screen for under the cooler also. 9 times out of 10 they're bad.

Before you take your fuel lines loose from the fuel filter housing put a zip tie around the lines so you don't have to chase the nuts on reinstall.
 
  #4  
Old 10-21-2010, 08:25 PM
rickey1172's Avatar
Diesel Fan
Thread Starter
Join Date: Oct 2009
Location: greenville sc
Posts: 99
Received 5 Likes on 5 Posts
Default

thanks for the tip on the nuts i thought about it when the first one went down the line. now they are all zip tied. 6 hours in and the turbo is about to come off.
 
  #5  
Old 10-26-2010, 08:20 PM
Hawkeyediesel's Avatar
Newbie
Join Date: Aug 2010
Location: Central Iowa
Posts: 6
Likes: 0
Received 3 Likes on 3 Posts
Default

Rickey,

Hey, how did the oil cooler replacement & EGR delete turn out. I'm kind of curious as I probably am going to do the same thing sometime this winter. Currently I am seeing 15 degree spreads unloaded running 70-75mph. I'll see 20 degree spreads a good portion of the time pulling the camper. The biggest thing I am noticing is that it is taking a lot longer for the oil to cool down, so I figure it is getting close to oil cooler time.

Just thought I would check in and see how it went for you and if you have any insight for someone else while everything was still fresh in your mind.
 
  #6  
Old 10-26-2010, 08:31 PM
rickey1172's Avatar
Diesel Fan
Thread Starter
Join Date: Oct 2009
Location: greenville sc
Posts: 99
Received 5 Likes on 5 Posts
Default

it took about 15 hours over 4 days. not any major problems just the drivers sideup pipe were a pain to get tightened up. no room for a wrench on the top . if you dont take the cab off you dont have much room to work on the back side of the motor. get some good blankets and lay them on the radiator and fan shroud. 3 days later my chest is still sore from laying on it for so long. all in all not too bad of a job. take your time and put all your bolts and small parts in baggies so you know where they go back. if you need any specific answers feel free to ask and i will try to help out any way i can.
 
  #7  
Old 10-27-2010, 08:15 PM
newman's Avatar
Diesel Enthusiast
Join Date: Jan 2009
Location: Tha sands of AZ
Posts: 161
Likes: 0
Received 4 Likes on 4 Posts
Default

Topside Creeper FTW! I would make sure you use quality 6pt sockets on the turbo bolts. They will be a nightmare if you round one off.
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Crabber0001
6.0L Performance
2
08-04-2015 12:30 PM
tim12valve
Ford Powerstroke 94-98 7.3L
0
05-06-2015 10:40 PM
Bighouse
Ford Powerstroke 03-07 6.0L
1
04-09-2015 06:51 PM
emilio2496
Ford Powerstroke 03-07 6.0L
8
01-13-2015 05:03 PM
bypass-21
Chevy/GMC 6.2L and 6.5L
1
12-15-2014 08:52 AM



Quick Reply: oil cooler rebuild



All times are GMT -5. The time now is 10:39 PM.