Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

06 dodge cummins overheats at idle

  #21  
Old 04-15-2011, 08:36 PM
wildbill's Avatar
BOMBARDIER

Join Date: Jul 2007
Location: Billlings, MT
Posts: 12,808
Received 667 Likes on 553 Posts
Default

Root Cause P0480 Fan Clutch:
FAN CLUTCH
WIRE HARNESS DAMAGED
OPEN FAN CLUTCH (K160) DRIVER CIRCUIT
(K160) DRIVER CIRCUIT SHORTED TO (K690) RETURN CIRCUIT
(K160) DRIVER CIRCUIT SHORTED TO BATTERY NEGATIVE
INTERMITTENT CONDITION
ECM



Root Cause P0483 Fan Speed:
OTHER DTC’S
(K161) SIGNAL CIRCUIT SHORT TO (K668) 5-VOLT SUPPLY CIRCUIT
(K161) SIGNAL CIRCUIT OPEN FROM ECM TO FAN CLUTCH ASSEMBLY
(K668) 5-VOLT SUPPLY CKT OPEN FROM ECM HARNESS CONNECTOR TO FAN CLUTCH HARNESS
CONNECTOR
INTERMITTENT CONDITION
(K161) SIGNAL CIRCUIT SHORTED TO (690) RETURN IN THE HARNESS
(K161) SIGNAL CIRCUIT SHORTED TO VOLTAGE
(K161) SIGNAL CIRCUIT IN ECM SHORTED TO GROUND INSIDE ECM
(K161) SIGNAL CIRCUIT SHORTED TO VOLTAGE IN THE ECM
(K668) 5-VOLT SUPPLY CIRCUIT IN ECM
 
  #22  
Old 04-16-2011, 04:29 PM
HaulinA's Avatar
Diesel Fan
Thread Starter
Join Date: Feb 2011
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Default

Read somewhere that if you ground the ground wire fan will lockup? How do you do this? We have to get this fan working so we can deliver load Monday.

We know this HAS to be an electrical problem. Fan still has tension on it.
 
  #23  
Old 04-16-2011, 11:43 PM
wildbill's Avatar
BOMBARDIER

Join Date: Jul 2007
Location: Billlings, MT
Posts: 12,808
Received 667 Likes on 553 Posts
Default

It only do it w/ the Edge installed?
 
  #24  
Old 04-17-2011, 10:39 AM
HaulinA's Avatar
Diesel Fan
Thread Starter
Join Date: Feb 2011
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Default

Difficult to say but yes. We disconnected harnesses to injectors and map sensors but left monitor on to be able to read temps. Truck ran really well last few weeks. Now we have taken the edge completely off the truck. As of late last night still can't get fan to engage.
A/c compressor cycles off and on, truck will cool well when driving. At stop, tried turning a/c to defrost to get fan to engage, nothing.

We still think it is electrical but don't know how to find it. The truck went form fan working extremely well up until Friday when pulling a load home in strong north wind. On the way in, fan engaged, temp stayed down..until we pulled off highway and rpms dropped. During one mile off the highway, to the house, temp went to 222 and climbing.

We disconnected batteries for a couple of hours yesterday to see if ecm would reset and clear codes...did not.

It appears that when fan is engaging properly and cooling engine, a/c function is poor and vice versa. Almost as if not enough power to do both.

Anymore advice suggestions would be greatly appreciated. This truck pays the bills!
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
JoeyMiR
24 Valve 2nd Gen Dodge Cummins 98.5-02
9
02-03-2018 10:05 PM
Taylor03
5.9 Liter CR Dodge Cummins 03-07
2
06-06-2015 11:09 AM
Linkbeltpower
For Sale
2
12-16-2014 08:44 AM
Linkbeltpower
For Sale
0
12-15-2014 10:52 PM
Diesel Bombers
General Diesel Related
0
11-04-2014 08:10 AM


Thread Tools
Search this Thread
Quick Reply: 06 dodge cummins overheats at idle



All times are GMT -5. The time now is 09:04 PM.