Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

Cummins wont turnover.

Thread Tools
 
Search this Thread
 
  #1  
Old 04-24-2010, 03:39 PM
vcustoms86's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2009
Location: Colorado Springs, CO
Posts: 614
Received 49 Likes on 39 Posts
Default Cummins wont turnover.

The truck made it fine from NC to CO. Didnt have any problems. Pulled in the driveway and shut it off. Went to start it to move her and nothing. Its acting like it not recognizing that the clutch is engaged. I have plenty of juice and im getting power to the starter but its acting like i dont have the clutch pushed in. Is there a sensor or something that tells the computer the clutch is in? Any help would be greatly appreciated. Made it home on leave now i dont have any thing to drive.
 
  #2  
Old 04-24-2010, 04:39 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

theres a sliding piece on the clutch pedal where it goes through the fire wall. might check ur fuses
 
  #3  
Old 04-24-2010, 04:39 PM
the_new_kid's Avatar
Diesel Enthusiast
Join Date: Aug 2009
Location: Fond du Lac WI
Posts: 139
Likes: 0
Received 1 Like on 1 Post
Default

have you tried to use something like a jumper wire to jump the starter solenoid? I would try that because if you get nothing then i would go for a starter otherwise you can override the clutch switch with a wire also and try it.

I know to some people this sounds like a bad idea but by bypassing stuff once and a while you can figure out what part of the equation is not working or malfunctioning.

On another note make sure when doing either of these methods be sure to have it out of gear on a level surface if possible and parking brake on.

Good luck
 
  #4  
Old 04-24-2010, 04:48 PM
vcustoms86's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2009
Location: Colorado Springs, CO
Posts: 614
Received 49 Likes on 39 Posts
Default

ok i was going through the fuses and the 20 amp for the starter was popped. swapt in a new one and it popped that one. the starter did try to turn over. Is something shorting it out?
 
  #5  
Old 04-24-2010, 04:52 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

ya it deffinately has a short somewhere if t poped that fues right away. check the wires around the starter
 
  #6  
Old 04-24-2010, 05:00 PM
vcustoms86's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2009
Location: Colorado Springs, CO
Posts: 614
Received 49 Likes on 39 Posts
Default

i did go through alot of moisture this whole trip too. Could some of the wires be wet and shorting out?
 
  #7  
Old 04-24-2010, 05:03 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

possibly
 
  #8  
Old 04-24-2010, 05:11 PM
vcustoms86's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2009
Location: Colorado Springs, CO
Posts: 614
Received 49 Likes on 39 Posts
Default

alright im gonna check all the wires.
 
  #9  
Old 04-24-2010, 08:13 PM
Diesel Nut's Avatar
Diesel Bombers Sponsor
Join Date: Jun 2007
Location: Sacramento
Posts: 1,321
Received 109 Likes on 87 Posts
Default

Swap the starter relay with something like the horn relay and replace the fuse. Relay could be shot. Next is the starter could be shorting internally or if the contacts are worn the contacts could be trying to pull to much amperage.
 
  #10  
Old 04-26-2010, 10:29 AM
vcustoms86's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2009
Location: Colorado Springs, CO
Posts: 614
Received 49 Likes on 39 Posts
Default

ok so i swapped the relays and still nothing. So before i started undoing cables i tossed in a 30 amp instead of a 20 amp for the starter. It wouldnt pop the 30 amp so i kept hitting the ignition to see if it would pop it and it started to try and tunrover. Hit it a few more times and she fired up. Let it run for a little bit and shut it down to make sure she would start again. She fired right back up. Im assuming that since it was real wet when i drove back and we had some pretty big puddles the starter just got real wet. Thanks everyone for thier help. She lives again and now i have something to drive while im home! Thanks guys!
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
JoeyMiR
24 Valve 2nd Gen Dodge Cummins 98.5-02
9
02-03-2018 10:05 PM
Shun70
Diesel Engine Conversions
0
09-21-2015 01:39 AM
Diesel Bombers
General Diesel Related
0
10-31-2014 08:10 AM
Diesel Bombers
General Diesel Related
0
10-24-2014 04:40 AM
Omingnome
Diesel In Distress - Support Ticket
5
10-20-2014 12:25 PM



Quick Reply: Cummins wont turnover.



All times are GMT -5. The time now is 03:40 PM.