5.9L Rotary Performance Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with Rotary Injection Pumps Related To Performance And Longevity

Cummins 12 valve electric fan install write up

Thread Tools
 
Search this Thread
 
  #41  
Old 03-03-2010, 01:30 AM
94cummins12v's Avatar
Diesel Bomber
Join Date: Jan 2008
Location: Havre mt
Posts: 4,525
Received 103 Likes on 99 Posts
Default

what is a way to be able to hook that probe into the radiator itself to get a more accurate reading
 
  #42  
Old 03-03-2010, 01:44 AM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

i just did what bobby told me. took off upper radiator hose the, drop it in the radiator, put the hose back on and tighten until it doesnt leak. worked for me.

i would have to add to this whole thing, that after driving it alot, i really dont like the operation of this controller at all with how it works. i am going to take it out, and put a coolant temp switch in that activates at 190. the controller seems to be garbage IMO. i wont be using one again
 
  #43  
Old 03-03-2010, 01:50 AM
94cummins12v's Avatar
Diesel Bomber
Join Date: Jan 2008
Location: Havre mt
Posts: 4,525
Received 103 Likes on 99 Posts
Default

i was looking at the napa one and it seemed cheesy any othe type of switch available to be able to activate the fans at a certain temp
 
  #44  
Old 03-03-2010, 12:35 PM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

there are thousands of switches avaialable. go to napa and ask them for their book on switches. just find one that turns on when it hits the temp you want. you can look on their website too
 
  #45  
Old 03-03-2010, 04:37 PM
tower_ofpower's Avatar
Diesel Bomber
Join Date: Jul 2009
Location: Kingwood, WV
Posts: 1,861
Received 86 Likes on 80 Posts
Default

are you using the adjustable temp one? we got the adjustable temp kit with the actual coolant probe and installed it in my bro in laws 69 mustang, drilled and tapped a hole in the manifold, cummins has provisions in the thermostat housing for this probe. it may be that the kit is configured to be used as a radiant heat prob and not a direct temp. could be causing your innaccuracies. only problem we ran into was shutting the engine down with the fan running, it'll continue to run the fan even after the radiator is cool as its gettin the temp reading from the manifold temp. a switch with a key off decay (if there's one out there?) or better yet a turbo timer, hook the hot circuit into the turbo timer, key on: it functions fine, key off it'll keep the engine and fan running until the turbo is cool allowing both cooling of engine and turbo.
 
  #46  
Old 03-03-2010, 09:42 PM
riesenbr549's Avatar
Diesel Fan
Join Date: Jan 2010
Location: Indiana
Posts: 19
Likes: 0
Received 0 Likes on 0 Posts
Default

U could also use a realy wired to your ign on as a ground interupter between the temp switch and the fan. A timer would be cool 2 just wire your fuel shut off and fan contoler or temp switch thru the timer so if you activate time and turn key off then the fan will run also if temp is hot enough . If the water temp is below lets say 190° then the fan wont run .You can get a simple 110v fan timer at a hardware store for like 12 bucks . There rated at 15-20 amp at 110v so they should handle a 45 amp 12v dc load or just wire on the switch side of the fan relay?
 
  #47  
Old 03-03-2010, 11:16 PM
tower_ofpower's Avatar
Diesel Bomber
Join Date: Jul 2009
Location: Kingwood, WV
Posts: 1,861
Received 86 Likes on 80 Posts
Default

Originally Posted by riesenbr549
U could also use a realy wired to your ign on as a ground interupter between the temp switch and the fan. A timer would be cool 2 just wire your fuel shut off and fan contoler or temp switch thru the timer so if you activate time and turn key off then the fan will run also if temp is hot enough . If the water temp is below lets say 190° then the fan wont run .You can get a simple 110v fan timer at a hardware store for like 12 bucks . There rated at 15-20 amp at 110v so they should handle a 45 amp 12v dc load or just wire on the switch side of the fan relay?
idk about that statement, seems awful funny that extention cords and most 110v appliances are only rated at 10 amp loads and automotive circuits can be up to 30A or better... voltage is electrical push, more voltage/push= less draw (amperage) play around with ohms and watts law abit. eitherway your suggestion may still work if its on the control circuit of the relay as they dont draw any signifficant ammount of current. either way, i still think this is gettin a bit too involved for what tltruckparts was really looking for. get a N.O temp switch for like 200-210* when it completes the circuit, fan comes on until X* when the switch breaks connection; problem solved. simple and bullet proof.
 
  #48  
Old 03-03-2010, 11:24 PM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

Originally Posted by tower_ofpower
idk about that statement, seems awful funny that extention cords and most 110v appliances are only rated at 10 amp loads and automotive circuits can be up to 30A or better... voltage is electrical push, more voltage/push= less draw (amperage) play around with ohms and watts law abit. eitherway your suggestion may still work if its on the control circuit of the relay as they dont draw any signifficant ammount of current. either way, i still think this is gettin a bit too involved for what tltruckparts was really looking for. get a N.O temp switch for like 200-210* when it completes the circuit, fan comes on until X* when the switch breaks connection; problem solved. simple and bullet proof.
exactly. thats what im going to do. i was thinking more along the lines of 185-195 but ya still the same theory. simple and easy. not just to do it
 
  #49  
Old 03-04-2010, 09:35 AM
94cummins12v's Avatar
Diesel Bomber
Join Date: Jan 2008
Location: Havre mt
Posts: 4,525
Received 103 Likes on 99 Posts
Default

ok so how exactly would i hook the fan up?
 
  #50  
Old 03-04-2010, 12:33 PM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

in place of the orange wire on the diagram i posted you would just replace that with the output of a temp switch thats all. its pretty easy
 


Quick Reply: Cummins 12 valve electric fan install write up



All times are GMT -5. The time now is 06:12 PM.