why wouldnt both fans work as pushers from the from threw the a/c condensor, intercooler and radiator? if i was to do this i would have 3/4" between the pullys and radiator were as a puller i cant run the condensor and have 1/2" between the radiator and pullys
 
  #32  
Old 02-21-2010, 02:11 AM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

it would work if you ran one in front of everything. but thats not an option for me id rather have my ac
 
  #33  
Old 02-21-2010, 02:54 PM
RSWORDS's Avatar
BOMBARDIER

Join Date: Mar 2007
Location: Gloucester, VA
Posts: 11,159
Received 918 Likes on 537 Posts
Default

Originally Posted by tltruckparts
hey bobby,

front of first valve cover to radiator is 10 1/2". what is it on a dodge?

the fan cranks itself if i disengage the fan manually, let it get to about 230, and turn the fan on, it cools it down to 190 in minutes even while driving
9"
 
  #34  
Old 02-21-2010, 04:11 PM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

Originally Posted by RSWORDS
9"
something cant be right there. because with a stock dodge fan on, i only have 1/8" clearance to the radiator in my truck. but on the dodge theres a ton more room
 
  #35  
Old 02-21-2010, 04:24 PM
RSWORDS's Avatar
BOMBARDIER

Join Date: Mar 2007
Location: Gloucester, VA
Posts: 11,159
Received 918 Likes on 537 Posts
Default

I don't know, just measured it. It was 9" from the front of the 1st Valve Cover to the back (engine side) of the radiator.
 
  #36  
Old 02-21-2010, 04:33 PM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

ill have to remeasure again later.

i got that thermostat housing shipped out to you the other day. you should see it beginning of this week if the post office doesnt pull any crap like they have been lately
 
  #37  
Old 02-21-2010, 04:54 PM
94cummins12v's Avatar
Diesel Bomber
Join Date: Jan 2008
Location: Havre mt
Posts: 4,525
Received 103 Likes on 99 Posts
Default

ya if i was to run both fans in front of everything i am still able to use my a/c but if i want it puller i cant run a/c and barely have room
 
  #38  
Old 02-21-2010, 05:34 PM
RSWORDS's Avatar
BOMBARDIER

Join Date: Mar 2007
Location: Gloucester, VA
Posts: 11,159
Received 918 Likes on 537 Posts
Default

Originally Posted by tltruckparts
ill have to remeasure again later.

i got that thermostat housing shipped out to you the other day. you should see it beginning of this week if the post office doesnt pull any crap like they have been lately
Cool, You get yours?
 
  #39  
Old 02-21-2010, 06:02 PM
tltruckparts's Avatar
Diesel Bomber
Thread Starter
Join Date: Aug 2009
Location: Lincoln, CA
Posts: 2,124
Received 102 Likes on 94 Posts
Default

not yet i think itll be here tomorrow
 
  #40  
Old 02-21-2010, 06:56 PM
RSWORDS's Avatar
BOMBARDIER

Join Date: Mar 2007
Location: Gloucester, VA
Posts: 11,159
Received 918 Likes on 537 Posts
Default

yeah i just looked, fed ex says tomorrow...
 