5.9 Liter CR Dodge Cummins 03-07 Discussion of 5.9 Liter Dodge Cummins Diesels with Common Rail Injection

Start with starting fluid no power when towing

Thread Tools
 
Search this Thread
 
  #1  
Old 09-10-2013, 01:54 PM
bud1989's Avatar
Newbie
Thread Starter
Join Date: Sep 2013
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Default Start with starting fluid no power when towing

I have a 2004.5 cummins. I had a line brake on the lift pump so i replaced the lift pump. After replacing it the starting got harder and harder. Now i have to start it with starting fluid. Pulled the pump to see if there was something wrong with it. Put it back together and it started right up for about 20 starts. It is throwing a code for p0148 fuel delivery problem. There is no power when towing. Could this be the lift pump starving the cp3 pump? Iv heard it could be injectors, cp3, fca, and the relief valve. Does anyone have any ideas? Would the lift pump cause this issue? Thank you.
 
  #2  
Old 09-11-2013, 08:16 AM
dangerous1965's Avatar
Diesel Bomber
Join Date: Dec 2008
Location: Escondido CA
Posts: 1,713
Received 111 Likes on 105 Posts
Default

Put a guage on the supply line to the CP3. WHile running pull the harness off the CP3 it should rattle real bad, that is full pressure through the pump. Plug it back in and it should recover in 30 seconds or less. Stop using starter fluid Very bad! Fix the problem! If your not able to take it to the dealer for diagnosis!
 
  #3  
Old 09-11-2013, 10:43 AM
bud1989's Avatar
Newbie
Thread Starter
Join Date: Sep 2013
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Default

I have pulled the harness from the cp3 pump it don't rattle to bad. An i have had the injectors tested. It all started when i swapped the pump. I'm going try a flow test on it tonight.
 
  #4  
Old 09-15-2013, 08:59 AM
dangerous1965's Avatar
Diesel Bomber
Join Date: Dec 2008
Location: Escondido CA
Posts: 1,713
Received 111 Likes on 105 Posts
Default

If it doesn't rattle real bad you have an issue with the CP3 or return flow is to high!

---AutoMerged DoublePost---

You really need some gauges for supply and CP3 pressure!
 

Last edited by dangerous1965; 09-15-2013 at 08:59 AM. Reason: Automerged Doublepost
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
GasItOut
12 Valve 2nd Gen Dodge Cummins 94-98
35
07-22-2015 01:11 PM
GasItOut
Alternative Fuels , Additives , Fluids
0
06-15-2015 11:30 PM
GasItOut
Diesel In Distress - Support Ticket
0
06-15-2015 11:25 PM



Quick Reply: Start with starting fluid no power when towing



All times are GMT -5. The time now is 05:32 PM.