24 Valve 2nd Gen Dodge Cummins 98.5-02 Discussion of 24 Valve 5.9 Liter Dodge Cummins Diesels with VP44 Injection Pumps
Sponsored by Trailer Plus

VP44 Replacement.

Thread Tools
 
Search this Thread
 
  #11  
Old 03-11-2008, 09:51 AM
Nitelord's Avatar
Diesel Bomber
Thread Starter
Join Date: Jul 2007
Location: Pottstown, PA
Posts: 4,980
Received 223 Likes on 193 Posts
Default

Update. Well I have fuel in the IP, but not coming out. My mechanic is going to replace the Banjo (valve) on the output of the pump and see if that changes anything..
After that, it looks like the pump (for whatever reason has given up the ghost...)

Thanks to all who have given opinions and advice on this thread.

I greatly appreciate everyone's willingness to take the time and provide the info...

I'll let you know how it turns out...
 
  #12  
Old 03-11-2008, 12:35 PM
Join Date: Mar 2007
Location: Western NC
Posts: 14,546
Received 843 Likes on 695 Posts
Default

Originally Posted by mysterync
The Vendor thats a big part in manufacturing the Monster is Here, Why not use him?

L


We also carry "Monster" VP44's.
 
The following users liked this post:
Nitelord (03-12-2008)
  #13  
Old 03-11-2008, 03:08 PM
mysterync's Avatar
Diesel Bombers Sponsor
Join Date: Mar 2007
Location: Blowing Rock,NC
Posts: 3,791
Received 367 Likes on 251 Posts
Default

Thanks for your Purchase Mark!!
We're Here to Support you in anything you need!

Thanks
Lucas
 
The following users liked this post:
Nitelord (03-12-2008)
  #14  
Old 03-12-2008, 10:54 AM
Nitelord's Avatar
Diesel Bomber
Thread Starter
Join Date: Jul 2007
Location: Pottstown, PA
Posts: 4,980
Received 223 Likes on 193 Posts
Default

Lucas, Thank you very much!!

As I said before, I appreciate all the advice I've gotten from all the Diesel Bomber members. The sponsors here are awesome...

The shop got the pump this morning and are installing it right now. I've asked them to leave the wire tap for some future date. Just install the pump and leave the Comp hooked to the MAP sensor.

I assume, that the Comp no longer provides timing with that setup.

Here's hoping all goes well....
 
  #15  
Old 03-12-2008, 10:58 AM
Join Date: Mar 2007
Location: Western NC
Posts: 14,546
Received 843 Likes on 695 Posts
Default

Sounds like its time for a Stealth Cover
 
The following users liked this post:
Nitelord (03-12-2008)
  #16  
Old 03-12-2008, 11:01 AM
Nitelord's Avatar
Diesel Bomber
Thread Starter
Join Date: Jul 2007
Location: Pottstown, PA
Posts: 4,980
Received 223 Likes on 193 Posts
Default

Yeah, I'm hoping that tap wasn't the cause of the original pumps demise.

Thanks again for everyones help!!!
You folks are the greatest.......
 
  #17  
Old 03-12-2008, 12:21 PM
HOTMOPR's Avatar
Diesel Enthusiast
Join Date: Mar 2007
Location: SW, Wa
Posts: 297
Received 15 Likes on 14 Posts
Default

Dude you should have them solder on the tap wire and cap it before they put the pump in. way easier to do it on the bench.
 
The following users liked this post:
Nitelord (03-12-2008)
  #18  
Old 03-12-2008, 12:27 PM
Nitelord's Avatar
Diesel Bomber
Thread Starter
Join Date: Jul 2007
Location: Pottstown, PA
Posts: 4,980
Received 223 Likes on 193 Posts
Default

I'll call em and see how far along they are.

Thanks...
 
  #19  
Old 03-12-2008, 03:41 PM
Mayfair's Avatar
Diesel Fan
Join Date: Mar 2007
Location: Philadelphia, PA / Mayfair
Posts: 42
Likes: 0
Received 3 Likes on 2 Posts
Default

What's the big deal with tapping the wire on the 44?

You're talking about when you tap it for like an Edge programmer right?
 
  #20  
Old 03-13-2008, 03:22 AM
Uncle Bubba's Avatar
BOMBARDIER
Join Date: Mar 2007
Location: Illinois?
Posts: 12,854
Received 1,112 Likes on 700 Posts
Default

Always just use the a plate to tap the wire. It's the only sure way to do it and make it clean and long lasting. Not to mention simple.
 


Quick Reply: VP44 Replacement.



All times are GMT -5. The time now is 05:28 PM.