24 Valve 2nd Gen Dodge Cummins 98.5-02 Discussion of 24 Valve 5.9 Liter Dodge Cummins Diesels with VP44 Injection Pumps
Sponsored by Trailer Plus

Can you??

Thread Tools
 
Search this Thread
 
Old Sep 15, 2012 | 11:24 AM
  #1  
cheer's Avatar
Thread Starter
|
Diesel Fan
Joined: Sep 2012
Posts: 62
Likes: 0
From: newliskeard ontario
Default Can you??

Im woundering if i can replace part of this line with a good rubber one does anyone know or is there to much pressure or something??or by pass it or something? Whats it for exactly?
 
Attached Thumbnails Can you??-img_00000191.jpg  

Last edited by cheer; Sep 15, 2012 at 11:27 AM.
Reply
Old Sep 15, 2012 | 11:41 AM
  #2  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

Factory transmission, or mild build, you will only have about 100psi max in the lines. A weel built will have up to 300psi in certain situations. You could cut the bad piece out, add rubber hose, and use at least 2 hose clamps per end.
 
Reply
Old Sep 15, 2012 | 11:59 AM
  #3  
biged681985's Avatar
BOMBARDIER

Joined: May 2008
Posts: 5,567
Likes: 338
From: Yellville, Arkansas
Default

Ideally you would want to splice the line with metal lines


B.E.D.S.
Big Ed's Diesel Service
 
Reply
Old Sep 15, 2012 | 12:02 PM
  #4  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

Did you find a cracked line, is that why you are thinking of splicing?
 
Reply
Old Sep 15, 2012 | 12:32 PM
  #5  
H.R.D's Avatar
Super Moderator
iTrader: (3)
Joined: Dec 2010
Posts: 3,765
Likes: 1,052
From: Las Cruces, NM
Default

You can get hydraulic soft line to replace the metal ones. I am sure you can even put those male fittings on it too.
 

Last edited by H.R.D; Sep 15, 2012 at 12:51 PM.
Reply
Old Sep 15, 2012 | 12:45 PM
  #6  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

My entire hose system for my trans cooling is 5/8" hydraulic hose with JIC ends. It is excessive, but it was readily available to me.
 
Reply
Old Sep 15, 2012 | 12:59 PM
  #7  
biged681985's Avatar
BOMBARDIER

Joined: May 2008
Posts: 5,567
Likes: 338
From: Yellville, Arkansas
Default

Or u can use hydraulic line like stated. But just using rubber line and hose clamps, I'm not a fan of that


B.E.D.S.
Big Ed's Diesel Service
 
Reply
Old Sep 15, 2012 | 01:26 PM
  #8  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

As non-ideal as it is, it is the way the factory cooler is connected to the system.
 
Reply