Diesel Bombers

Diesel Bombers (https://www.dieselbombers.com/)
-   24 Valve 2nd Gen Dodge Cummins 98.5-02 (https://www.dieselbombers.com/24-valve-2nd-gen-dodge-cummins-98-5-02/)
-   -   Can you?? (https://www.dieselbombers.com/24-valve-2nd-gen-dodge-cummins-98-5-02/102312-can-you.html)

cheer 09-15-2012 11:24 AM

Can you??
 
1 Attachment(s)
Im woundering if i can replace part of this line with a good rubber one does anyone know or is there to much pressure or something??or by pass it or something? Whats it for exactly?

RAW 09-15-2012 11:41 AM

Factory transmission, or mild build, you will only have about 100psi max in the lines. A weel built will have up to 300psi in certain situations. You could cut the bad piece out, add rubber hose, and use at least 2 hose clamps per end.

biged681985 09-15-2012 11:59 AM

Ideally you would want to splice the line with metal lines


B.E.D.S.
Big Ed's Diesel Service

RAW 09-15-2012 12:02 PM

Did you find a cracked line, is that why you are thinking of splicing?

H.R.D 09-15-2012 12:32 PM

You can get hydraulic soft line to replace the metal ones. I am sure you can even put those male fittings on it too.

RAW 09-15-2012 12:45 PM

My entire hose system for my trans cooling is 5/8" hydraulic hose with JIC ends. It is excessive, but it was readily available to me.

biged681985 09-15-2012 12:59 PM

Or u can use hydraulic line like stated. But just using rubber line and hose clamps, I'm not a fan of that


B.E.D.S.
Big Ed's Diesel Service

RAW 09-15-2012 01:26 PM

As non-ideal as it is, it is the way the factory cooler is connected to the system.


All times are GMT -5. The time now is 03:53 AM.


© 2024 MH Sub I, LLC dba Internet Brands