Default Heater Grid

My heater grid is not coming on. If I manually run a ground wire to the negative side of the two relays they both come on (the relay coil has power with the ignition on but no ground). Also if I disconnect the small negative wire and reconnect it the relay it will come on for a split second. So my question is what controls the negative wire on each of the two relays for the heater grid?
 
Reply
Old Nov 1, 2011 | 12:02 PM
  #2  
daveO's Avatar
Diesel Bomber
Joined: May 2009
Posts: 1,030
Likes: 171
From: Pottstown, PA
Default

I know the PCM controls the grid heater cycling. I'm not sure if it's a switched ground or not.

---AutoMerged DoublePost---

So after looking at the wiring diagram in the FSM, it does look like the PCM controls the ground side of the relay.
 

Last edited by daveO; Nov 1, 2011 at 12:02 PM. Reason: Automerged Doublepost
Reply
Old Nov 1, 2011 | 08:30 PM
  #3  
kieron_kohlmann's Avatar
Diesel Enthusiast
Joined: Feb 2010
Posts: 352
Likes: 31
From: Wisconsin
Default

Computers almost always switch ground.
 
Reply
Old Nov 1, 2011 | 09:11 PM
  #4  
kwebb412's Avatar
Thread Starter
|
Diesel Fan
Joined: Jul 2011
Posts: 24
Likes: 0
Default

Thank you for the help. The intake heater grid was litterally hacked out of my intake manifold by a previous owner and I replaced it to prepare for the cold weather. I beleive the reason why it was not coming on is my weather here in AZ is not cold enough yet.... I found the following link to better explain how they work Grid Heaters it is unclear if the relays are triggered by ground or 12v but considering I always have 12v if the ignition is on it is a negative trigger.... Thanks again for the help.
 
Reply
Old Nov 14, 2011 | 02:18 PM
  #5  
Scott R.'s Avatar
Newbie
Joined: Nov 2011
Posts: 7
Likes: 0
Default

i dont use the grid heater i think it is to hard on the altenator i plug in when it is very cold and let the motor warm up in the a.m. before work. i have done this for three years and not had any trouble.
 
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
dodge2014
1st Generation Dodge Cummins 89-93
2
Apr 16, 2015 08:54 PM
95 cummin
12 Valve 2nd Gen Dodge Cummins 94-98
0
Jan 21, 2015 11:54 AM
Rooster24v
24 Valve 2nd Gen Dodge Cummins 98.5-02
15
Jan 4, 2015 08:20 PM
Low_Life_Style
5.9 Liter CR Dodge Cummins 03-07
16
Nov 29, 2014 06:28 PM
justinsbeck
24 Valve 2nd Gen Dodge Cummins 98.5-02
1
Nov 22, 2014 03:03 AM




All times are GMT -5. The time now is 11:16 AM.