2007 F350-defrost vent problem
I don't know if anyone can help, but the other day I realized that vents won't switch from defrost. The blower motor seems to be working fine, it just won't switch from defrost to floor or face. Anyone else have any issues with this or know of a solution? thanks
That may be if the vacuum line at one of the hubs is screwed up... what if the vacuum line in the passenger foot well is the problem?
Keith
Keith
I haven't had the 4wd engaged? Would that make a difference?
---AutoMerged DoublePost---
I checked the 4wd and it is engaging.
---AutoMerged DoublePost---
I checked the 4wd and it is engaging.
Last edited by merdth6; Dec 26, 2012 at 09:41 AM. Reason: Automerged Doublepost
Behind the glove compartment is where the air is redirected, I'd start there leak checking the line by applying vacuum to them. The one that you disconnect that doesn't hold vacuum is your winner, track it down and find the leak. If all hold vacuum, then look at the vacuum motors that open/close the doors.