Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

NEED HELP FAST!!!

Thread Tools
 
Search this Thread
 
  #1  
Old 04-14-2017, 08:41 PM
diesel virgin's Avatar
Diesel Fan
Thread Starter
Join Date: Apr 2016
Posts: 44
Received 2 Likes on 2 Posts
Default NEED HELP FAST!!!

My 94 6.5td is acting up again.
it starts running fine. When it gets warm it will cut off while driving. It usaly fires right back up.
but i have to keep my foot on the accelerator to keep it going.
And this last time the truck was cool. Drove less than quarter mile and truck shut off. I had to bypass lift pump to get it going again but that didnt sovle the problem. It would cut out and stall the whole way home.
My frist thought was pdm i put im my spare no change. I just replace the ops and the lift pump relay still same problem.
It has a new sending unit, new lift pump, new injection pump, new pmd relocated, new ops, new lift pump relay and all new lines through out.
I am showing 2 codes 32 and 33 egr and vaccuum pump. Can an issue with the vaccumm cause the truck to act like this. If not what else could it be.
 
  #2  
Old 04-21-2017, 06:29 PM
j johnson's Avatar
Diesel Enthusiast
Join Date: Jan 2009
Posts: 136
Received 7 Likes on 7 Posts
Default

could be your in tank pickup getting some trash and stopping it up .....i would start there and work forward.....scott
 