Chevy/GMC 6.2L and 6.5L Discussion of Chevy and GMC Trucks with 6.2L and 6.5L Diesel Engines

6.2 problems

Thread Tools
 
Search this Thread
 
  #1  
Old 08-05-2012, 06:09 PM
metalhead152's Avatar
Newbie
Thread Starter
Join Date: Aug 2012
Posts: 3
Likes: 0
Received 0 Likes on 0 Posts
Default 6.2 problems

Hi guys, I have a 1500 GMC 6.2 with running issues. It wont stay running on a colder morning (around 15 Celsius) I cant hear the fuel pump run every time I crank, sometimes it will sometime it wont. I wired in a light parallel to the fuel pump to see if it was getting power/ground and so far it has both (the light stays lit) sometimes. >_>

How does the fuel pump get its power? I understand the oil pressure switch sends power to the relay then the relay sends power to the pump? Is that correct?

Thanks for the help guys :P
 
  #2  
Old 08-05-2012, 06:30 PM
Mayhem's Avatar
Diesel Wrench
Join Date: Jun 2012
Location: Middle of nowhere Tn
Posts: 1,255
Received 128 Likes on 121 Posts
Default

Yes the oil sending unit controls the LP if you run a wire from the positive terminal on you're battery to the G terminal on the OBD1 port under you're dash after opening the T valve and fuel comes out of it you should probally change the OPS
 
  #3  
Old 08-05-2012, 07:00 PM
metalhead152's Avatar
Newbie
Thread Starter
Join Date: Aug 2012
Posts: 3
Likes: 0
Received 0 Likes on 0 Posts
Default

So sending power down the G terminal Will send it through the OPS, and then to the Relay (causing it to *click*) and ultimately the LP? Sorry I don't have a schematic. Thanks for the quick response!
 
  #4  
Old 08-05-2012, 08:09 PM
Mayhem's Avatar
Diesel Wrench
Join Date: Jun 2012
Location: Middle of nowhere Tn
Posts: 1,255
Received 128 Likes on 121 Posts
Default

sorry I meant to put this on here earlier
 
Attached Thumbnails 6.2 problems-aldl-1.jpg  
  #5  
Old 08-06-2012, 10:08 AM
metalhead152's Avatar
Newbie
Thread Starter
Join Date: Aug 2012
Posts: 3
Likes: 0
Received 0 Likes on 0 Posts
Default

I should change the ops if fuel comes out? Putting power to terminal G in NOT suppose to make the LP run?
 
  #6  
Old 08-06-2012, 10:27 AM
Mayhem's Avatar
Diesel Wrench
Join Date: Jun 2012
Location: Middle of nowhere Tn
Posts: 1,255
Received 128 Likes on 121 Posts
Default

Power to terminal G will make LP run if it is good this is helpful when bleeding the fuel system as well
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
jedder21
Chevy/GMC 6.2L and 6.5L
3
03-07-2015 09:47 PM
joealto91
Chevy/GMC 6.2L and 6.5L
2
12-08-2014 06:54 PM
Caveman94
Chevy/GMC 6.2L and 6.5L
2
12-08-2014 12:21 PM
DanielC559
Chevy/GMC 6.2L and 6.5L
7
12-08-2014 06:20 AM
jdcarter
Chevy/GMC 6.2L and 6.5L
1
11-29-2014 11:31 AM



Quick Reply: 6.2 problems