Default a/c freeze up

my evaporator keeps freezing over,any advice? to much freon or not enuff?
 
Reply
Old Jul 17, 2011 | 01:19 PM
  #2  
BACONBITSFORU's Avatar
Diesel Wrench
iTrader: (1)
Joined: May 2011
Posts: 516
Likes: 30
From: Texarkana, Texas
Default a/c freeze up

Where do you love?
 
Reply
Old Jul 17, 2011 | 01:20 PM
  #3  
BACONBITSFORU's Avatar
Diesel Wrench
iTrader: (1)
Joined: May 2011
Posts: 516
Likes: 30
From: Texarkana, Texas
Default a/c freeze up

*live stupid iPhone
 
Reply
Old Jul 17, 2011 | 01:27 PM
  #4  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

I'm not too sure if these truck have a freeze switch, but if they do I would be suspect of it.
 
Reply
Old Jul 17, 2011 | 01:33 PM
  #5  
txswm58's Avatar
Thread Starter
|
Newbie
Joined: Sep 2008
Posts: 8
Likes: 0
Default

texas were its over a 100 ever day
 
Reply
Old Jul 17, 2011 | 01:35 PM
  #6  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

Can you hear the A/C compressor cycling? It shouldn't stay on all the time.
 
Reply
Old Jul 17, 2011 | 02:00 PM
  #7  
txswm58's Avatar
Thread Starter
|
Newbie
Joined: Sep 2008
Posts: 8
Likes: 0
Default

no its not cylcing
 
Reply
Old Jul 17, 2011 | 05:06 PM
  #8  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

While I'm looking this up, does the A/C compressor turn off when you select vents only?
 
Reply
Old Jul 17, 2011 | 05:14 PM
  #9  
RAW's Avatar
RAW
Administrator

iTrader: (1)
Joined: Aug 2009
Posts: 6,218
Likes: 684
From: Alberta
Default

Freeze–up Control A/C Low Pressure Switch Accumulator mounted

Low psi Control Opens < 22-24 psi Resets > 37-43 psi

High psi Control Opens > 450- 490 psi Resets <270 - 330 psi
mounted on discharge line, near compressor


If you have a set of gauges, this may diagnose if a high, or low pressure switch has failed closed. With the gauges attached, if the low side goes below 22-24 PSI and the compressor is still running, the low pressure switch is bad. If the high side goes over 450-490 PSI, the high pressure switch is bad.

It may also be a case of too much freon in the system. When did the symptoms start? Did anything change from when it worked well, and until now?
 
Reply
Old Jul 17, 2011 | 05:47 PM
  #10  
txswm58's Avatar
Thread Starter
|
Newbie
Joined: Sep 2008
Posts: 8
Likes: 0
Default

yes it turns off,thats how i thaw it out.takes a few minutes

---AutoMerged DoublePost---

i change the evaporator coil in the dash the blower motor and orfice tube,been freezin up since
 

Last edited by txswm58; Jul 17, 2011 at 05:47 PM. Reason: Automerged Doublepost