I installed my FASS 150HD in July 2010. Ever since about October 2010 my fuel gauge hasn't been working like it used to. Once i get to about 150 miles on a tank, the needle just kind of sticks around 3/4 of a tank until i get to about 400 miles and then fill up again. Sometimes it will go as far as 1/2 a tank but then it stays and it still isn't right. I've been watching the trip ever since I first got my truck, and usually 300 miles is right at half a tank. For the past month the needle on the fuel gauge only goes down to about 3/4 of a tank until i fill it up.
 
  #2  
Old 02-07-2011, 02:18 PM
Red_Rattler's Avatar
High Tech Redneck

Join Date: Nov 2007
Location: Columbus WI
Posts: 6,730
Received 496 Likes on 397 Posts
Default

Did you get the fuel basket back in the tank in the same orientation that it came out? Could be hitting the side of the tank or the float could have got bent? But either way to see what's goin on or to fix it the tanks coming back out.
 
  #3  
Old 02-07-2011, 04:31 PM
GuyWithA24Valve's Avatar
Diesel Wrench
Thread Starter
Join Date: Feb 2010
Location: Lynd, Minnesota
Posts: 931
Received 95 Likes on 72 Posts
Default

Originally Posted by Red_Rattler
Did you get the fuel basket back in the tank in the same orientation that it came out? Could be hitting the side of the tank or the float could have got bent? But either way to see what's goin on or to fix it the tanks coming back out.
I didn't put a draw straw in when i hooked up my Fass so I have never had the basket out. I wish I would've. and the return is running into the filler neck
 

Last edited by GuyWithA24Valve; 02-07-2011 at 04:33 PM.
  #4  
Old 02-08-2011, 10:54 AM
connermcpherson's Avatar
Diesel Enthusiast
Join Date: Jan 2009
Location: SARASOTA, FL
Posts: 369
Received 27 Likes on 23 Posts
Default

I have the same problem with my fuel gauge but thats really a Dodge problem, every Ram ive owned has a fuel sending unit problem. Instead of doing a draw straw, im dropping the tank and installing a sump on the bottom of the tank, and adding a sending unit from Auto Meter to really know what kinda fuel i have
 
  #5  
Old 02-08-2011, 11:00 AM
RAW's Avatar
RAW
RAW is offline
Administrator

iTrader: (1)
Join Date: Aug 2009
Location: Alberta
Posts: 6,218
Received 684 Likes on 549 Posts
Default

My buddy had a similar issue, his kept getting worse and worse. At first 1/4 was empty, then 1/2, and fianlly 3/4. It ended up being the fuel sender, of course. If I were to need a new sending unit I would get one of these:
Modified liberty fuel module

It already has the high flow draw straw installed, and won't give you any 1/4 tank issues. Return fuel from your engine, and fuel pump are returned to the fuel basket, keeping it as full as possible.
 
  #6  
Old 08-20-2014, 04:45 PM
WestTexasOutlaw's Avatar
Diesel Fan
Join Date: Mar 2013
Location: Abilene TX
Posts: 24
Received 0 Likes on 0 Posts
Default

Originally Posted by connermcpherson
I have the same problem with my fuel gauge but thats really a Dodge problem, every Ram ive owned has a fuel sending unit problem. Instead of doing a draw straw, im dropping the tank and installing a sump on the bottom of the tank, and adding a sending unit from Auto Meter to really know what kinda fuel i have
I am having the same issue. I replaced my flsu and while my bed was off I sumped it and installed an air dog 150 worked for a good 3 months then stopped working again...
 
  #7  
Old 08-21-2014, 10:44 PM
Anh Chà n's Avatar
Diesel Fan
Join Date: Jul 2014
Posts: 34
Received 2 Likes on 1 Post
Default

I have the same issue with my truck and what happing is event worse .. I was filling a full tank and driving it to the 1/4 so i can calculate how is the truck use on fuel . Then i ended up runing out of fuel on a day after work but the gauge is not event go below 1/4 yet ... I call for help and got some diesel fill in but the truck is not start ...then after too many atemp i blew the starter feu ... So i have to call a tow truck to tow mine back to the shop ( my work place ) and tow truck is takes forever ... The time when my truck is broke down is 6 pm and i got home is 12 am . But not done yet : next morning i fill the truck with haft tank of fuel , check on starter , fuses .. Etc but the truck still wont start , it really a nightmare to me to find out what is wrong with it ... Then finally it start after i bleed the fuel lines ... So this is one bad exp i hade with the fuel gauge
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Jet A Fuel
6.7 Liter Dodge Cummins 2013+
8
10-21-2015 03:30 PM
Jet A Fuel
6.7 Liter Dodge Cummins 07.5-12
3
08-03-2015 10:45 AM
Jmohr52
24 Valve 2nd Gen Dodge Cummins 98.5-02
1
02-08-2015 10:39 PM
dawnrogerl
Air Dog
0
01-23-2015 03:09 PM
dawnrogerl
24 Valve 2nd Gen Dodge Cummins 98.5-02
0
01-23-2015 02:15 PM



Quick Reply: Sending Unit?



All times are GMT -5. The time now is 11:35 PM.