Default lights pulse bright and dim while truck runnin?

while the truck is runnin even after it warms up the dash light, head light marker light and even the lights in the radio pulse at any rpm. checked power at grid heater and there is no power goin to it so its not cycling on and off. new battery have clean conections voltage regulator only a year old and alt is only 4 months old. the voltage gauge has slight movement in it. grounded block to firewall block to frame and battery to frame and block. any one got any ideas i could try
 
  #2  
Old 11-14-2010, 10:34 PM
diesel pap's Avatar
Site Sponsor - Mighty Diesel
Join Date: Dec 2008
Location: West Virginia
Posts: 4,184
Received 213 Likes on 200 Posts
Default

those regulators are junk. i keep one in the glove box all the time.
 
  #3  
Old 11-15-2010, 10:35 AM
1stGen1990's Avatar
Diesel Enthusiast
Join Date: Mar 2010
Location: Powell Butte, Oregon
Posts: 139
Received 4 Likes on 4 Posts
Default

yeah mine does the same thing. Where is the regulator even at?
 
  #4  
Old 11-15-2010, 03:51 PM
cumminskid92's Avatar
Diesel Enthusiast
Join Date: Dec 2008
Posts: 305
Received 4 Likes on 4 Posts
Default

It should be on the fire wall on the passenger side. that is where it is at on mine anyways. That sounds like it is your problem
 
  #5  
Old 11-15-2010, 08:43 PM
RSWORDS's Avatar
BOMBARDIER

Join Date: Mar 2007
Location: Gloucester, VA
Posts: 11,159
Received 918 Likes on 537 Posts
Default

That and the body ground is crap on these trucks. Replace the ground wire from the battery to the core support a good heavy gauge wire.
 
The following users liked this post:
big bad diesel 416 (11-15-2010)
  #6  
Old 11-15-2010, 10:30 PM
big bad diesel 416's Avatar
Site Sponsor
Join Date: Apr 2009
Location: Lexington SC
Posts: 3,719
Received 636 Likes on 254 Posts
Default

when in doubt ground it out I learned that the hard way
 
  #7  
Old 11-18-2010, 11:59 AM
blazier18's Avatar
Diesel Bomber
Join Date: Jul 2010
Location: knox county tn
Posts: 1,176
Received 28 Likes on 28 Posts
Default

i have a 91 too and my is doing the same thing where exacty is it located?
 
  #8  
Old 11-18-2010, 12:28 PM
Vargafarm's Avatar
Diesel Fan
Join Date: May 2009
Posts: 41
Likes: 0
Received 1 Like on 1 Post
Default

I replaced my alternator with 1 from PA performance, internal regulator and bolt up.
voltage is rock steady now.
 
  #9  
Old 11-21-2010, 10:34 PM
rick390's Avatar
Diesel Fan
Join Date: Oct 2010
Location: alamosa co.
Posts: 13
Likes: 0
Received 0 Likes on 0 Posts
Default

the reg is usually on the fire wall just above the rear valve cover , 2 wire connector with hold down spring , unplug the connector and lights will dim but will be steady , if so reg is junk
 
  #10  
Old 11-26-2010, 06:24 AM
92W250's Avatar
Diesel Fan
Join Date: Oct 2009
Location: Jacksonville, FL
Posts: 71
Received 0 Likes on 0 Posts
Default

I had a similar issue and then went through several regulators. I even replaced the Alternator and crank sensor in pursuit of my issue. Never did get it truly fixed, but at least it charges again.
 