12 Valve 2nd Gen Dodge Cummins 94-98 Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with P7100 Injection Pumps

shutoff

Thread Tools
 
Search this Thread
 
Old Feb 17, 2010 | 10:53 AM
  #1  
cummins95's Avatar
Thread Starter
|
Diesel Wrench
Joined: Apr 2009
Posts: 772
Likes: 48
From: Sullivan County, PA
Default shutoff

last night i was messin around under the hood, had the afc off, swapped out the washer messed with it a bit then put everything back together. i drove over to my girlfriends house n turned the key off n it stayed runnin for about 2 seconds, then shut off. it did it again this mornin when i stopped for fuel. but when i got to college, it shut off just fine. i've smelled the exhaust, no oil smell, no blue smoke or anything, n i checked the turbo n there's no sign of a leak so im thinkin the shutoff solenoid is stickin. how should i go about checkin it n cleanin it? can i use carb cleaner or brake clean?
 
Reply
Old Feb 17, 2010 | 12:06 PM
  #2  
cummins_guy's Avatar
Diesel Bombers Sponsor
Joined: Apr 2009
Posts: 474
Likes: 26
Default

your shut off solenoid is going bad or is bad.
 
Reply
Old Feb 17, 2010 | 12:20 PM
  #3  
oglejust's Avatar
Diesel Wrench
Joined: Oct 2008
Posts: 556
Likes: 19
From: paris illinois
Default

or u messed up the linkage when u worked on it
 
Reply
Old Feb 17, 2010 | 01:46 PM
  #4  
PhilipR's Avatar
Diesel Wrench
Joined: Nov 2009
Posts: 629
Likes: 44
Default

Originally Posted by oglejust
or u messed up the linkage when u worked on it
That's what I think.....it might be binding up.....you'll burn it up in short order if it is. Better check it out o make sure it moves up and down freely.
 
Reply
Old Feb 17, 2010 | 08:38 PM
  #5  
over worked's Avatar
Diesel Fan
Joined: Oct 2009
Posts: 18
Likes: 1
From: michigan
Default

check that shut off switch and linkage you dont wont to hert the pump
good luck
 
Reply
Old Feb 17, 2010 | 08:41 PM
  #6  
joey's Avatar
Diesel Enthusiast
Joined: Sep 2009
Posts: 310
Likes: 2
From: rockport texas
Default

Some of them have a ball joint at the end and others are just strait rod and when you pull the solenoid over to get the afc off you will bend the rod and it will bind up.
 
Reply
Old Feb 19, 2010 | 03:48 AM
  #7  
Coaly's Avatar
Newbie
Joined: Feb 2010
Posts: 5
Likes: 0
Default

does your fusable link have a good positive battery connection? mine ran for a good 5 seconds(with the key in the off position) after i pulled the batteries, then reinstalled them, i think its a blue wire to the positive battery terminal.
 
Reply
Old Feb 19, 2010 | 05:32 AM
  #8  
cummins95's Avatar
Thread Starter
|
Diesel Wrench
Joined: Apr 2009
Posts: 772
Likes: 48
From: Sullivan County, PA
Default

i got er fixed. it was just hangin up, musta gotten tweaked when i was messin with the afc
 