12 Valve 2nd Gen Dodge Cummins 94-98 Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with P7100 Injection Pumps

shutoff

Thread Tools
 
Search this Thread
 
  #1  
Old 02-17-2010, 10:53 AM
cummins95's Avatar
Diesel Wrench
Thread Starter
Join Date: Apr 2009
Location: Sullivan County, PA
Posts: 772
Received 48 Likes on 25 Posts
Default shutoff

last night i was messin around under the hood, had the afc off, swapped out the washer messed with it a bit then put everything back together. i drove over to my girlfriends house n turned the key off n it stayed runnin for about 2 seconds, then shut off. it did it again this mornin when i stopped for fuel. but when i got to college, it shut off just fine. i've smelled the exhaust, no oil smell, no blue smoke or anything, n i checked the turbo n there's no sign of a leak so im thinkin the shutoff solenoid is stickin. how should i go about checkin it n cleanin it? can i use carb cleaner or brake clean?
 
  #2  
Old 02-17-2010, 12:06 PM
cummins_guy's Avatar
Diesel Bombers Sponsor
Join Date: Apr 2009
Posts: 474
Received 26 Likes on 22 Posts
Default

your shut off solenoid is going bad or is bad.
 
  #3  
Old 02-17-2010, 12:20 PM
oglejust's Avatar
Diesel Wrench
Join Date: Oct 2008
Location: paris illinois
Posts: 556
Received 19 Likes on 19 Posts
Default

or u messed up the linkage when u worked on it
 
  #4  
Old 02-17-2010, 01:46 PM
PhilipR's Avatar
Diesel Wrench
Join Date: Nov 2009
Posts: 629
Received 44 Likes on 30 Posts
Default

Originally Posted by oglejust
or u messed up the linkage when u worked on it
That's what I think.....it might be binding up.....you'll burn it up in short order if it is. Better check it out o make sure it moves up and down freely.
 
  #5  
Old 02-17-2010, 08:38 PM
over worked's Avatar
Diesel Fan
Join Date: Oct 2009
Location: michigan
Posts: 18
Received 1 Like on 1 Post
Default

check that shut off switch and linkage you dont wont to hert the pump
good luck
 
  #6  
Old 02-17-2010, 08:41 PM
joey's Avatar
Diesel Enthusiast
Join Date: Sep 2009
Location: rockport texas
Posts: 310
Received 2 Likes on 2 Posts
Default

Some of them have a ball joint at the end and others are just strait rod and when you pull the solenoid over to get the afc off you will bend the rod and it will bind up.
 
  #7  
Old 02-19-2010, 03:48 AM
Coaly's Avatar
Newbie
Join Date: Feb 2010
Posts: 5
Likes: 0
Received 0 Likes on 0 Posts
Default

does your fusable link have a good positive battery connection? mine ran for a good 5 seconds(with the key in the off position) after i pulled the batteries, then reinstalled them, i think its a blue wire to the positive battery terminal.
 
  #8  
Old 02-19-2010, 05:32 AM
cummins95's Avatar
Diesel Wrench
Thread Starter
Join Date: Apr 2009
Location: Sullivan County, PA
Posts: 772
Received 48 Likes on 25 Posts
Default

i got er fixed. it was just hangin up, musta gotten tweaked when i was messin with the afc
 