TC lockup switch not working

Thread Tools
 
Search this Thread
 
Old Aug 5, 2014 | 07:49 PM
  #1  
gear_grinder's Avatar
Thread Starter
|
Diesel Fan
Joined: Aug 2014
Posts: 14
Likes: 0
Default TC lockup switch not working

Okay, I have b connector pin 11 tapped into (not cut/interrupted) and the jumper wire across the relay switched circuit. I have a good ground on the firewall for the switch to connect to, the switch is good. What strikes me as strange is that according to my multi meter using the continuity test function it shows the tapped b11 pin always grounded. The trans acts completely normal. Anyone have or heard of this issue?
 
Reply
Old Aug 5, 2014 | 08:08 PM
  #2  
JBearSVT's Avatar
Diesel Bomber
Joined: Oct 2010
Posts: 1,325
Likes: 59
From: New England
Default

For some reason, I thought it was B13. Hm. It's been awhile. What color is it?
 
Reply
Old Aug 5, 2014 | 08:26 PM
  #3  
gear_grinder's Avatar
Thread Starter
|
Diesel Fan
Joined: Aug 2014
Posts: 14
Likes: 0
Default

Originally Posted by JBearSVT
For some reason, I thought it was B13. Hm. It's been awhile. What color is it?
Orange with a black tracer

http://www.tstproducts.com/Torque%20...p%20Switch.pdf
 
Reply
Old Aug 6, 2014 | 07:45 AM
  #4  
LostSoul71's Avatar
Diesel Enthusiast
Joined: May 2014
Posts: 163
Likes: 1
From: Niagara Falls ON CA
Default

Did you jump the relay?
 
Reply
Old Aug 6, 2014 | 07:49 AM
  #5  
gear_grinder's Avatar
Thread Starter
|
Diesel Fan
Joined: Aug 2014
Posts: 14
Likes: 0
Default

Originally Posted by gear_grinder
jumper wire across the relay switched circuit.
yep
 
Reply
Old Aug 6, 2014 | 12:05 PM
  #6  
4x4manonbroke's Avatar
Diesel Bomber
Joined: Jun 2010
Posts: 3,202
Likes: 143
From: Tacoma
Default

Solenoid is bad or clutch in TC is toast ..
 
Reply
Old Aug 6, 2014 | 12:58 PM
  #7  
gear_grinder's Avatar
Thread Starter
|
Diesel Fan
Joined: Aug 2014
Posts: 14
Likes: 0
Default

Originally Posted by gear_grinder
The trans acts completely normal.
The TC and sol are probably fine seeing that it locks normally in 4th gear
 
Reply
Old Aug 6, 2014 | 01:46 PM
  #8  
LostSoul71's Avatar
Diesel Enthusiast
Joined: May 2014
Posts: 163
Likes: 1
From: Niagara Falls ON CA
Default

May sound silly but you are 100% on the #11 and that the switch you are using is good?
 
Reply
Old Aug 6, 2014 | 02:04 PM
  #9  
gear_grinder's Avatar
Thread Starter
|
Diesel Fan
Joined: Aug 2014
Posts: 14
Likes: 0
Default

Tested the switch yesterday, it's good. I'm installing gauges tonight and I'll double checked on the wire, but I'm sure i check continuity from wire after I pulled the insulation off and the b11 pin
 
Reply
Old Aug 6, 2014 | 07:57 PM
  #10  
4x4manonbroke's Avatar
Diesel Bomber
Joined: Jun 2010
Posts: 3,202
Likes: 143
From: Tacoma
Default

Originally Posted by gear_grinder
The TC and sol are probably fine seeing that it locks normally in 4th gear
Sounds like the wiring is wrong .. odd though .. Do you have the wiring diagram ? I can E-mail it to you .. mine is a 95 .. might help

But then again .. mine is a RH not an RE
 
Reply