Diesel Bombers

Diesel Bombers (https://www.dieselbombers.com/)
-   12 Valve 2nd Gen Dodge Cummins 94-98 (https://www.dieselbombers.com/12-valve-2nd-gen-dodge-cummins-94-98/)
-   -   no low end power (https://www.dieselbombers.com/12-valve-2nd-gen-dodge-cummins-94-98/114347-no-low-end-power.html)

smokedout 08-06-2013 07:45 PM

no low end power
 
Bought truck with no plate. Did the common afc mods and threw a #100 in. Wasn't impressed. I took it back out and now the truck is not getting as much fuel as before. No smoke at all is how I can tell. I thought no plate ment more low end fuel. Star wheel is all the way loose now to see what's the deal. Still nothing.

4x4manonbroke 08-06-2013 08:21 PM

maybe smoke screw .... :humm: .... ummm timing ? what all have you done for mods ?

smokedout 08-06-2013 09:10 PM

Thought I had my sig. Set up but I guess not. Stage 2 ddp injectors, 16.5*, afc mods the smoke screw is all the way backed out, stiffer spring, 4 inch, 3k, boost elbow, etc all the basic. Ran fine right before I yanked the plate

---AutoMerged DoublePost---

Thought I had my sig. Set up but I guess not. Stage 2 ddp injectors, 16.5*, afc mods the smoke screw is all the way backed out, stiffer spring, 4 inch, 3k, boost elbow, etc all the basic. Ran fine right before I yanked the plate

Benjamin 08-06-2013 10:36 PM

did you re-attach the hose to the AFC housing? if you remove that or it creates a leak like a crack the AFC foot will restrict fuel as it thinks it is in a low/no boost situation. there should be some sort of an o-ring that acts as a compression fitting to the housing and the tube will go to the intake plenum OR over to the turbo and attach to the line that the wastegate is also connected to.

smokedout 08-07-2013 05:22 PM

The hose is fine. I moved the afc housing forward up all the way. It helped with the power but still not getting the fuel it was before I put the plate in

Benjamin 08-08-2013 07:39 PM

I bet the governor arm is getting hung under the leading edge of the plate. that will cause this problem too. there is a procedure around here somewhere that will show the proper way to adjust the arm, as it has to be adjusted, for the arm to work properly, when a plate is moved from the factory position.

Benjamin 08-11-2013 08:37 PM

12V Cummins Governor Lever Adjustment

just in case you haven't figured this out, I am 99.9% sure this will cure your problem.

smokedout 08-15-2013 09:28 PM

Not really since I'm plate less

---AutoMerged DoublePost---

Thanks though

4x4manonbroke 08-16-2013 09:22 PM

redundant question ....... have you checked your valve adjustments ? ....

smokedout 08-17-2013 08:51 PM

No and how plz


All times are GMT -5. The time now is 04:01 AM.


© 2024 MH Sub I, LLC dba Internet Brands