24 Valve 2nd Gen Dodge Cummins 98.5-02 Discussion of 24 Valve 5.9 Liter Dodge Cummins Diesels with VP44 Injection Pumps
Sponsored by Trailer Plus

starter contacts

Thread Tools
 
Search this Thread
 
  #1  
Old 12-30-2012, 08:07 PM
sixshooter's Avatar
Diesel Fan
Thread Starter
Join Date: Apr 2012
Location: dayton ohio
Posts: 89
Likes: 0
Received 0 Likes on 0 Posts
Default starter contacts

i just replaced my contacts a couple days ago one contact was pretty much gone the other was fine. someone told me that when this happens its either a problem in my ground or low voltage if this is true can someone elaborate on this i was told i have low voltage but my multimeter shows over 14v with the lights and heater on it does however jump from 14 to 12 i am told this is the grid heater cycling.
 
  #2  
Old 12-30-2012, 08:17 PM
diesel pap's Avatar
Site Sponsor - Mighty Diesel
Join Date: Dec 2008
Location: West Virginia
Posts: 4,184
Received 213 Likes on 200 Posts
Default

every one i ever took apart have one way worse
 
  #3  
Old 12-30-2012, 09:49 PM
Zukifreek's Avatar
Diesel Fan
Join Date: Apr 2012
Location: Rimbey Alberta
Posts: 40
Received 5 Likes on 5 Posts
Default

Originally Posted by diesel pap
every one i ever took apart have one way worse
Exactly. thats how every one I've ever had apart is too. Same on gas jobs, mini vans bobcats etc. That style of starter is used on many different engines and they all wear like that in my experience. Crank away you will be good for a long time again
 
  #4  
Old 12-31-2012, 01:23 PM
sixshooter's Avatar
Diesel Fan
Thread Starter
Join Date: Apr 2012
Location: dayton ohio
Posts: 89
Likes: 0
Received 0 Likes on 0 Posts
Default

thanks guys i feel a lot better about about it now. what do you guys think about the low voltage is it normal to jump from 14 to 12v if it is the heater cycling should the alt. compensate for this.
 
  #5  
Old 12-31-2012, 01:50 PM
Big Bill's Avatar
Diesel Fan
Join Date: Dec 2007
Location: Nova Scotia Canada
Posts: 80
Received 0 Likes on 0 Posts
Default

Originally Posted by sixshooter
thanks guys i feel a lot better about about it now. what do you guys think about the low voltage is it normal to jump from 14 to 12v if it is the heater cycling should the alt. compensate for this.
Don't worry. This is normal. Your altenator can't keep up. This is another reason you have two batteries.
 
  #6  
Old 12-31-2012, 04:24 PM
sixshooter's Avatar
Diesel Fan
Thread Starter
Join Date: Apr 2012
Location: dayton ohio
Posts: 89
Likes: 0
Received 0 Likes on 0 Posts
Default

do you think this could affect the the outcome of the test the parts store done?
 
  #7  
Old 12-31-2012, 07:59 PM
Zukifreek's Avatar
Diesel Fan
Join Date: Apr 2012
Location: Rimbey Alberta
Posts: 40
Received 5 Likes on 5 Posts
Default

If they were testing it while the grids were powered up the voltage reading would have been low. Your alt is putting out maximum amps during grid heating. When your amps are high the voltage drops. You would need an altenator 3 times bigger to not show a voltage drop during your grids cycling time, they use a ton of power as they are more or less a short circuited piece of metal that is meant to get super hot. If your voltage is between 13.6ish and 14.8ish during regular operation you are fine. They were probably trying to sell another $250 altenator
 
  #8  
Old 01-01-2013, 05:20 PM
sixshooter's Avatar
Diesel Fan
Thread Starter
Join Date: Apr 2012
Location: dayton ohio
Posts: 89
Likes: 0
Received 0 Likes on 0 Posts
Default

ok thanks hopefully that is all it is really appreciate the info guys.
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
leocanuck
6.0L Performance
0
09-27-2015 06:05 PM
klein444
Chevy/GMC 6.2L and 6.5L
13
06-20-2015 11:48 PM
james2562
Chevy/GMC 6.2L and 6.5L
5
02-05-2015 09:05 PM
nevadagramm
24 Valve 2nd Gen Dodge Cummins 98.5-02
2
10-17-2014 07:59 PM
thunderball52
Diesel In Distress - Support Ticket
1
10-06-2014 08:08 PM



Quick Reply: starter contacts



All times are GMT -5. The time now is 01:44 AM.