Diesel Bombers

Diesel Bombers (https://www.dieselbombers.com/)
-   Ford 83-94 6.9 and 7.3L General (https://www.dieselbombers.com/ford-83-94-6-9-7-3l-general/)
-   -   7.3 glow plug controler issue (https://www.dieselbombers.com/ford-83-94-6-9-7-3l-general/86815-7-3-glow-plug-controler-issue.html)

backwoodsracing 11-25-2011 09:07 PM

7.3 glow plug controler issue
 
i just replaced the solenoid on the GP controller and it sends power to the GP's all the time, i have lost one set of GP's to this put new set in today and ran push button to solenoid where the ignition power comes in. my question is can i leave it this way and if so how long can i hold the button before it damages GP's. does'nt the controller turn on for a second and shutoff many times through its cycle when it works.

thank you for all your input:tu:

wildbill 11-25-2011 09:11 PM

Sounds like a faulty controller. The way you got it wired now will work. When you first hit the glow plugs, go 8 seconds then start the engine. If it's cold, cycle them 6 times, 3 sec's at a time with 15 sec's between.


All times are GMT -5. The time now is 09:17 AM.


© 2024 MH Sub I, LLC dba Internet Brands