hillbilly1970 03-02-2009 09:10 AM

03 2500 Ram wont start
 
Can't get this truck to start on it own. You can give it a squirt of ether and it will fire right up and run fine. Once you cut it back off it will not start back untill you squirt it with ether again. The fuel pump in the tank has been changed and the rubber fuel lines have been replaced. Any help would be greatly appreciated. It is not flashing any codes at all....:argh:

wildbill 03-02-2009 09:29 AM

Sounds like a faulty FCA, faulty CP3, rail pressure relief has popped, or your needing new injectors.

BTW, any mods done to the truck??

hillbilly1970 03-02-2009 10:29 AM


Originally Posted by wildbill (Post 297223)
Sounds like a faulty FCA, faulty CP3, rail pressure relief has popped, or your needing new injectors.

BTW, any mods done to the truck??

Can you be a little more specific for me.... I am not as diesel smart as most people on here. I am still learning... As for the truck it is bone stock with 140,000

wildbill 03-02-2009 11:59 AM

FCA (kinda like a govenor) is limits the amount of fuel entering the CP3 (high pressure injector pump. Out put 6k-24k wop). From there it send fuel to a rail, which then it goes into the injectors. The rail pressure relief pops when pressure exceeds 28k, to keep the injectors from blowing. How did it act before the no start?? Run rough, white smoke??

ltr450 03-02-2009 02:20 PM

sounds like injectors to me

hillbilly1970 03-03-2009 09:13 AM


Originally Posted by wildbill (Post 297300)
FCA (kinda like a govenor) is limits the amount of fuel entering the CP3 (high pressure injector pump. Out put 6k-24k wop). From there it send fuel to a rail, which then it goes into the injectors. The rail pressure relief pops when pressure exceeds 28k, to keep the injectors from blowing. How did it act before the no start?? Run rough, white smoke??

The truck seemed to run good. It started out hard to start and it gradually got worse.When it first statred doing it we replaced the fuel filters and it would start right up. After we done this 5 or 6 times it has gotten to where this no longer helps. It also got to where you could bleed it off at the fuel filter and it would start but that no longer helps....

wildbill 03-03-2009 10:10 AM

Could be the fuel pump is out to. If you bring it in, there will have you switch to the in-tank design ($500).

Also, if the older style went out, sends metal through your CP3 and injectors.

hillbilly1970 03-03-2009 02:58 PM


Originally Posted by wildbill (Post 297820)
Could be the fuel pump is out to. If you bring it in, there will have you switch to the in-tank design ($500).

Also, if the older style went out, sends metal through your CP3 and injectors.

They replaced the one in the tank and the lines coming to the motor. So do you think it could have sent some metal to the cp3 or an injector? Is there any way you can tell if this has happened?

wildbill 03-03-2009 03:01 PM

If it's in the tank, the fuel filter would stop the metal particles. With 180k, chances are your injectors are in need of replacement.

hillbilly1970 03-07-2009 08:26 PM

We finally figured it out. It had a bad injector...... thanks for all the help