mopwr2004a 04-03-2019 12:45 AM

Hard start
 
Have a intermittent starting problem.
First crank up of the day it starts first hit of the key.
Drive some then the problem starts.
Have to crank the engine over alot for it to start. This doesn't happen all the time. I may drive it several days with no issues.
The trk is a 07 w/5.9 - 6spd

11B/11C 04-03-2019 11:54 AM

When it cranks but doesn't start, what's your cranking RP?

mopwr2004a 04-03-2019 09:02 PM

Engine spins fine, just struggles to fire off
 
Turns over like supposed to. Not turning over slowly

Bigg Redd 04-03-2019 10:27 PM

Mine had similar issue about 3 yrs ago. turned out to be FCA (fuel control actuator). no issues since. Any code(s)??

mopwr2004a 04-04-2019 07:52 AM

No codes at all, where is this part located your talking about.
I was thinking lift pump or something of that nature

Bigg Redd 04-04-2019 08:28 AM


Originally Posted by mopwr2004a (Post 1155030)
No codes at all, where is this part located your talking about.
I was thinking lift pump or something of that nature

The FCA is located right at the injection pump. Its held on by 2 small bolts, and has a wire connector attached. If your truck fails to start, disconnect the connector and try to start it. If it starts, then the FCA is faulty, however don't run the engine for more than a few seconds.