new to this help plz
I have a 03 ford SD. 6.0l . Went into the store came out and try to start, it just turned over. I shot ether into the intake and it fired off. Ran above ide but as soon as I let it idle or drop pressure at the injector it died. I monitored the injector pressures as soon as it drops below 500 it dies. I have changed to oil, the fuel pump runs a while to pump up. I dont think its that because once I get it to start it will run for a couple of min . or 3. ---------
help
help
ICP code, I used a analyizer and the demand pressure is at 654 and the supply is at 524, can it still be the high pressure oil pump if I have pressure. Someone said that if I had a leak in the high pressure pump i wouldnt have that kind of pressure (524) ---looking at the IPR
Just a update on the problem of not starting. It was the injector pressure regulator. Replaced both the sensor and regulator just because they are a pain to get to. Thanks for the information guys
Thread
Thread Starter
Forum
Replies
Last Post
itvinny
Diesel In Distress - Support Ticket
1
Jun 19, 2015 09:26 PM
itvinny
Diesel In Distress - Support Ticket
1
Jun 19, 2015 09:21 PM