Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

7.3 suddenly died

Thread Tools
 
Search this Thread
 
  #1  
Old 05-13-2018, 06:58 PM
Jshe485017's Avatar
Newbie
Thread Starter
Join Date: May 2018
Posts: 1
Likes: 0
Received 0 Likes on 0 Posts
Default 7.3 suddenly died

Hi. I have a '99 f350 with the 7.3L. I was leaving work the other day and the truck just died, no warning at all. I check the fuses and found the fuel bowl heater had blowen so i disconnected the heat and replaced the fuse. The truck cranks but no attempt at starting. I had a diesel mechanic come out and look at the truck. He was positive that the IPR was bad. After doing my own research I found that the ICP was the original in the truck. The truck has just over 250,000 miles on it. So I replaced both the ICP and the IPR. Note just a couple of years ago i had the CPS replaced. (boy that was a long trip) I had a friend come out with an ODB2 tool and we couldn't find anything wrong. RPM's come up a couple hundred while cranking. Oil pressure comes up to 3000ish. He ran an injector test and we could hear all 8 injectors clicking. The fuel filter bowl fills with fuel. What else could it be? Any help would be much appreciated.
 
  #2  
Old 06-03-2018, 01:35 PM
Tinylogger's Avatar
Newbie
Join Date: Jun 2018
Location: Colorado
Posts: 1
Likes: 0
Received 0 Likes on 0 Posts
Default

If your CPS was bad it wouldn't show any rpms on the tach. After the fuel heater fuse popped you replaced fuse and unplugged fuel heater then cranked it or unplugged fuel after you cranked it I would recheck fuse? Is the ipr clean where the solenoid slides onto it and the little nut is tight? Have you tried leaving ipc unplugged when cranking?
 
  #3  
Old 06-03-2018, 04:48 PM
Hillbilly1's Avatar
Diesel Enthusiast
Join Date: Mar 2017
Posts: 154
Received 5 Likes on 5 Posts
Default

The fuel heater fuse blown on a 99 that I had just a couple of days after I had the fuel filter changed. The dealer said an aftermarket filter that included the cap had been installed, and that was what shorted out the heater. I had them put an OEM cap and filter on it, and never had any more trouble from it. Sounds like yours is a little more in depth.
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
ultimatejustin7.3
Diesel In Distress - Support Ticket
8
01-24-2013 11:47 PM
pbarrett1
Ford Powerstroke 99-03 7.3L
11
12-09-2011 10:51 PM
geddy's uncle
Jeep Liberty
4
03-06-2011 09:10 AM
Dankster
Diesel In Distress - Support Ticket
4
12-03-2010 06:36 PM
farmboy
Diesel In Distress - Support Ticket
11
01-05-2010 01:00 PM



Quick Reply: 7.3 suddenly died



All times are GMT -5. The time now is 09:23 PM.