Hi i am a new member from Ont and i am running out of ideas on how to get my 6.0
power stroke running, it started with the intermittent stall then a few days ago just quit and refuses to start, i checked for ficm and have 48 volts at cranking, oil pressure gauge goes to 35 or so at long crank, checked at icp sensor and it only registers between .40 and .50 volts at cranking, i was told i need at least .80 to register to show that i have at least 500 psi for the injectors, i have voltage at injectors and they do buzz at key on, have lots of fuel at filter and good flow rate, do not even get a single puff of smoke from exhaust or any indication that it is even trying to start, even with a shot of ether it just cranks, , ALSO it does not show any code faults period on mine and a friends testers, i would really like to get this going at home with out having to take it to a garage, thanks Scotty |