Default PEX Waterlines

anybody messed with this stuff..............I just ordered close to 400 bucks worth of stuff so I can totally re-do my cabin........my friend has the crimping pliers so I am just gonna borrow them


http://www.houseneeds.com/shop/plumb...FR6AWAodZQ4E5g
 
  #2  
Old 07-07-2007, 04:41 PM
Mr. Miyagi's Avatar
Diesel Bomber
Join Date: Mar 2007
Location: Olympic Peninsula
Posts: 2,564
Received 285 Likes on 193 Posts
Default

Almost as easy as running electrical wire.......after using it, I can't believe I ever wasted so much time sweating copper.

I think you'll like it, Kev....
 
  #3  
Old 07-07-2007, 04:45 PM
redneckbuckeye's Avatar
Diesel Bomber
Join Date: Mar 2007
Location: Sheridan,IN
Posts: 1,339
Received 75 Likes on 52 Posts
Default

I was looking at doing it in a concrete floor in a grid for radiant heat. Seams to be what a lot of builders are using. The builder I work for uses it.
 
  #4  
Old 07-07-2007, 04:50 PM
Whit's Avatar
Site Mascot
Thread Starter
Join Date: Mar 2007
Location: Why-homing
Posts: 16,010
Received 940 Likes on 701 Posts
Default

I see they have some other PEX recommended for the heating projects....cant member the details but its on that website
 
  #5  
Old 07-10-2007, 03:01 PM
dozerboy's Avatar
Diesel Wrench
Join Date: Apr 2007
Location: TX
Posts: 988
Received 55 Likes on 44 Posts
Default

Depends on your water if you have very harsh water like in Socal it won't last but a few years then you will have thousands of pinhole leaks. I don't see it ever lasting as long as copper, but maybe long enough you can justified replacing it in 10+ years.
 
  #6  
Old 07-10-2007, 03:05 PM
CHenry's Avatar
Vegistrokin Bombardier
Join Date: Mar 2007
Location: Oklahoma
Posts: 1,705
Received 121 Likes on 77 Posts
Default

Originally Posted by dozerboy
Depends on your water if you have very harsh water like in Socal it won't last but a few years then you will have thousands of pinhole leaks. I don't see it ever lasting as long as copper, but maybe long enough you can justified replacing it in 10+ years.
I've never heard this before...thats scary cause its all under my house slab and in the walls... 7 years old now.
 
  #7  
Old 07-10-2007, 10:33 PM
Mr. Miyagi's Avatar
Diesel Bomber
Join Date: Mar 2007
Location: Olympic Peninsula
Posts: 2,564
Received 285 Likes on 193 Posts
Default

Any evidence on what causes the leakage?
 
  #8  
Old 07-11-2007, 10:08 AM
CHenry's Avatar
Vegistrokin Bombardier
Join Date: Mar 2007
Location: Oklahoma
Posts: 1,705
Received 121 Likes on 77 Posts
Default

Originally Posted by Radio Flyer
Any evidence on what causes the leakage?

:pc:
 
  #9  
Old 07-11-2007, 10:48 AM
Ratsun's Avatar
Diesel Fan
Join Date: Mar 2007
Location: Wet Coast Canada
Posts: 55
Likes: 0
Received 4 Likes on 4 Posts
Default

Originally Posted by dozerboy
Depends on your water if you have very harsh water like in Socal it won't last but a few years then you will have thousands of pinhole leaks. I don't see it ever lasting as long as copper, but maybe long enough you can justified replacing it in 10+ years.
Are you sure your not referring to the older Polly-B and not the I-Pex?
I have yet to hear of a failure with the Pex pipe, a few problems with poor install procedures but not the products fault. The stuff for in-floor slabs is different than just the regular stuff.
 
  #10  
Old 07-11-2007, 06:46 PM
Plhorseman's Avatar
Diesel Enthusiast
Join Date: Mar 2007
Location: Mesquite, TX
Posts: 374
Received 25 Likes on 22 Posts
Default

Originally Posted by Ratsun
Are you sure your not referring to the older Polly-B and not the I-Pex?
I have yet to hear of a failure with the Pex pipe, a few problems with poor install procedures but not the products fault. The stuff for in-floor slabs is different than just the regular stuff.
I agree. Pex will stand up to alot, provided the installation is done correctly. Make sure that you treat the fittings correctly and you should be fine. Are you gonna be on well water or city water? Like any other piping, if you have excessive minerals in your water, it is gonna affect the life of the pipe and fittings. If the water has a high mineral count or high TDS (total disolved solids), you might consider a softner.
 