Ignition Switch OFF Engine continues to Run 24v 2001
I have a 2001 Cummins 2500 24v 235HP. When I shut off the Ignition the engine keeps running. Could this be the ASD? or the ignition switch? or ???..I need some troubleshooting guidence. Thanks for your help.-sam
|
Does this truck have any mods or changes whatsoever to the electrical wiring?
|
IT HAS THE EDGE COMPUTER/TUNER INSTALLED. I BOUGHT THE TRUCK WITH 121000 MILES AND IT NOW HAS 132000. I HAVE HAD NO PROBLEMS WITH THE TRUCK. OVER THE LAST MONTH I HAVE NOTICED THAT THE MOTOR TOOK A SECOND OR TWO TO SHUT DOWN AFTER CUTTING THE IGNITION SWITCH OFF. THANKS FOR THE REPLY.-SAM
|
I would unhook the edge and see if it continues to do it. Quick & easy to rule it out of the equasion.
|
Thanks for the reply. I pulled the Automatic Shutdown relay to stop the engine and removed the battery cables. The cleared up the problem for now. I am not sure if it was the ASD or the removal of power to another system that did it. :humm:
|
Doesnt Edge have a turbo timer???
|
edge has a egt turbo timer to get the egts down before shutting off. its adjustable or maybe it could be the fuel shutoff solenoid???
|
Originally Posted by BloodyDuck
(Post 905884)
I have a 2001 Cummins 2500 24v 235HP. When I shut off the Ignition the engine keeps running. Could this be the ASD? or the ignition switch? or ???..I need some troubleshooting guidence. Thanks for your help.-sam
Mine does the same thing .... has Edge /Attitude ....it might be a safety feature. |
I tried putting my foot on the brake when shutting down...no help...the problem is intermittent... and happens once out of 9 or 10 shutdowns... thanks for the input guys....
|
Have you tried swapping the relay with a known good relay, or just replacing it?
|