Cody Cummins 10-08-2011 11:00 AM

Grid heater issue?
 
Lately ive noticed my truck having problems starting, on hot days itll have no pro lem, and when its cold enough for wait to start light stay on for a few seconds it has no problem, but on the days in between hot and cold it doesnt wanna start, ill turn the key half way, wait to start light will go out, and i have to sit there and crank it for like 10 seconds to get it to fire then i get a big cloud of white smoke so i know getting fuel is not the issue, do you all think its the grid heater?

Sent from my PG86100 using Tapatalk

empty wallet 10-08-2011 12:06 PM

how's that vp doin? gettin any codes?

Cody Cummins 10-08-2011 12:43 PM

Re: Grid heater issue?
 
Doing fine, constant 15 psi fuel pressure going to her its about a year old

Sent from my PG86100 using Tapatalk

empty wallet 10-08-2011 01:37 PM

Well you have a pusher pump so 15psi at the VP inlet doesn't mean much, next time you try to start it and think it might have a hard time, crack an injector line and see if any fuel comes out. Most of the posts I've seen on this type of issue means bad VP, mechanical failure due to cracked diaphram.

Cody Cummins 10-08-2011 02:29 PM

Re: Grid heater issue?
 
I was told at the diewel shop to leave the psi where its at, and the the truck has plenty of fuel it puts out a big white puff once it starts, and it only does it when its in warm temps. Hot and cold cold weather it starts just fine

Edit, and it does it all the time when its warm out not just once in a while

Sent from my PG86100 using Tapatalk

empty wallet 10-08-2011 02:51 PM

A big black puff on startup sounds right... white is not good, did anybody crack an injector line? You can be seeing 15psi and not getting it thru the injection pump because of a damaged rotor or diaphram. Do some searching. These trucks shouldn't be hard starting, ever. ESPECIALLY hard warm/hot starts, signature symptom of damaged vp44

Cody Cummins 10-08-2011 03:04 PM

Re: Grid heater issue?
 
I did have a code once it was pump timing calibration, but im sure it was from my smarty, the truck isnt always hard to start just after it sits for a few hours, but if i run it for a bit and turn it off and it starts up just fine

Sent from my PG86100 using Tapatalk

Cody Cummins 10-08-2011 04:10 PM

Re: Grid heater issue?
 
Think i just found the issue i scanned it for codes and im getting a p0382 intake air heater relay and a p0236 map sensor too high too long, im gueseing the relay is whats causing it


Sent from my PG86100 using Tapatalk

empty wallet 10-08-2011 04:35 PM

Case closed... glad to hear it's nothing serious :rocking:

JSPulliam21 10-08-2011 09:57 PM

Yep, if the wiring and relays are ok then the only thing left is the heater. Mine had one coil go bad, and it was smoking bad white when cold. New used heater off an 06 solved the issue.