24 Valve 2nd Gen Dodge Cummins 98.5-02 Discussion of 24 Valve 5.9 Liter Dodge Cummins Diesels with VP44 Injection Pumps
Sponsored by Trailer Plus

no heat

  #1  
Old 12-17-2008, 06:09 PM
Blue01cummins's Avatar
Diesel Enthusiast
Thread Starter
Join Date: Dec 2008
Location: St.louis MO
Posts: 171
Likes: 0
Received 3 Likes on 3 Posts
Default no heat

My heat will not work the truck heats up to 190 but i have no heat inside? The blower still works and it also still changes the vents when i turn the ****. I get a little bit of heat when the **** is on low but once i turn it up nothing? I put a hose to the heater core water comes out fine? i even changed the heater control in the dash with one that a buddy had but still nothing?

Thanks Rich
 
  #2  
Old 12-17-2008, 06:21 PM
Mr.Krabs's Avatar
Diesel Wrench
Join Date: Mar 2008
Location: Lewiston Idaho
Posts: 808
Received 26 Likes on 23 Posts
Default

There should be a flapper somewhere in the heater to let air come in from part of the box where the heater core is,I'm betting the actuator there is not working,cause' of a vacuum hose,or bad diaphragm.
I've never had that problem,and I don't know where my darn book is,but that should be the problem.
 
  #3  
Old 12-17-2008, 09:16 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

hey man, mine does the exact same thing. if ya get yours fixed before i do let me know what it was. ill do the same.
 
  #4  
Old 12-17-2008, 10:13 PM
Uncle Bubba's Avatar
BOMBARDIER
Join Date: Mar 2007
Location: Illinois?
Posts: 12,854
Received 1,112 Likes on 700 Posts
Default

If you do a search for heater here in the cummins section another guy had this same problem within the last month or so and his post should be in here someplace.

Nevermind, that post was Biged himself. Guess you never got it fixed eh.

If you have hot coolant getting through the heater core it almost has to be the flapper door not moving right cutting the supply of cold air off and it's vacuum operated.
 

Last edited by Uncle Bubba; 12-17-2008 at 10:17 PM.
  #5  
Old 12-18-2008, 05:47 PM
Mopar1973Man's Avatar
Diesel Wrench
Join Date: Mar 2007
Location: New Meadows, Idaho
Posts: 820
Received 132 Likes on 94 Posts
Default

Sound like the blend door is stuck... It not vacuum driven... Its got a stepper motor that moves the door. So check the rheostat (control), check the wiring, and the last step is the blend door...(Might require removal of the HVAC system to fix it...)

I've got a write up on diagnostics...
Heater

Before performing the following tests, refer to Cooling for the procedures to check the engine coolant level and flow, engine coolant reserve/recovery system operation, accessory drive belt condition and tension, radiator air flow and the fan drive operation. Also be certain that the accessory vacuum supply line is connected at the engine vacuum source.
Maximum Heater Output

Engine coolant is delivered to the heater core through two heater hoses. With the engine idling at normal operating temperature, set the temperature control **** in the full hot position, the mode control switch **** in the floor position, and the blower motor switch **** in the highest speed position. Using a test thermometer, check the temperature of the air being discharged at the HVAC housing floor outlets. Compare the test thermometer reading to the Temperature Reference chart
If the floor outlet air temperature is too low, refer to Cooling to check the engine coolant temperature specifications. Both of the heater hoses should be hot to the touch. The coolant return heater hose should be slightly cooler than the coolant supply heater hose. If the return hose is much cooler than the supply hose, locate and repair the engine coolant flow obstruction in the cooling system. Refer to Cooling for the procedures. An alternate method of checking heater performance is to use a DRBIIIt scan tool to monitor the engine coolant temperature. The floor outlet air temperature reading should be no more than 4.5° C (40°F) lower than the engine coolant temperature reading.
Obstructed Coolant Flow

Possible locations or causes of obstructed coolant flow:
  • Faulty water pump.
  • Faulty thermostat.
  • Pinched or kinked heater hoses.
  • Improper heater hose routing.
  • Plugged heater hoses or supply and return ports at the cooling system connections.
  • A plugged heater core.
If proper coolant flow through the cooling system is verified, and heater outlet air temperature is still low, a mechanical problem may exist.
Mechanical Problems

Possible locations or causes of insufficient heat:
  • An obstructed cowl air intake.
  • Obstructed heater system outlets.
  • A faulty, obstructed or improperly installed blend door.
  • A faulty blower system.
  • A faulty a/c heater control.
 
  #6  
Old 12-18-2008, 09:31 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

hey, my blend door is good. ive taken the electric actuator off the bottom and you can turn it by hand. you can here it when it hits one side, then when it tuns and hits the other.
when i first turn it on vent it is hot for about one second. then it goes to cool. not cold but right there on the verge of being cold.
i got two buddies who work at a dodge dealer.
1. one of them told me it might be a plastic bag got sucked up somehow and is blocking the heater core, but in my thinking if it is blocking the heater core, how can air get past it to blow out the vents.
2. the other said i might have only one tube flowing coolant through it. the rest are plugged up. thats y i can get water to go through it but still no hot air.
what do yall think about these two guesstimations?
 
  #7  
Old 12-18-2008, 10:30 PM
Mr.Krabs's Avatar
Diesel Wrench
Join Date: Mar 2008
Location: Lewiston Idaho
Posts: 808
Received 26 Likes on 23 Posts
Default

I think #1 is more likely than #2.
I hear it's a real bitch to get the heater core out...
 
  #8  
Old 12-18-2008, 11:48 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

ive already pulled the dash once for this reason. well to fix it from only blowing on the feet. should have changed the heater core while i had it out, but the guy helping me talked me out of it.
 
  #9  
Old 12-19-2008, 09:56 AM
Mr.Krabs's Avatar
Diesel Wrench
Join Date: Mar 2008
Location: Lewiston Idaho
Posts: 808
Received 26 Likes on 23 Posts
Default

DOH!
 
  #10  
Old 12-19-2008, 09:51 PM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

i hate listening to other people. first a plasma cutter ordeal then a dash or deal. what next, i hope nothing.
 