12 Valve 2nd Gen Dodge Cummins 94-98 Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with P7100 Injection Pumps

Aftermarket fuel shutoff solenoid.

Thread Tools
 
Search this Thread
 
  #1  
Old 12-28-2017, 11:48 AM
Mr Bird's Avatar
Newbie
Thread Starter
Join Date: Dec 2017
Posts: 4
Received 0 Likes on 0 Posts
Default Aftermarket fuel shutoff solenoid.

Has anyone used an aftermarket fuel shut off solenoid from RockAuto, or O'Reilly's Etc? My truck is starting to act up on starting, I'm having to manually flip the solenoid up to start the truck
 
  #2  
Old 01-02-2018, 04:10 PM
Blair@BD's Avatar
FormerVendor
Join Date: Feb 2010
Location: ABBOTSFORD BC
Posts: 76
Received 14 Likes on 12 Posts
  #3  
Old 01-14-2018, 01:23 PM
chucks's Avatar
Diesel Fan
Join Date: Mar 2010
Posts: 28
Likes: 0
Received 1 Like on 1 Post
Default

I have purchased one from Rock Auto. It was significantly cheaper, but I did have to do a little monkeying around to have it work. It has been working fine, only one issue since install. The solenoid mounting bolts loosened off and had to find the correct bolt torque so the plunger does not bind in the solenoid. Just check the solenoid relay before changing the solenoid. A cheaper fix if it is the relay. I had to change mine after putting in the solenoid.
chucks
 
The following users liked this post:
Mr Bird (01-21-2018)
  #4  
Old 01-20-2018, 08:56 AM
JBearSVT's Avatar
Diesel Bomber
Join Date: Oct 2010
Location: New England
Posts: 1,325
Likes: 0
Received 59 Likes on 58 Posts
Default

I replaced mine with multiple OEM and aftermarket ones, including the relay, and eventually got so fed up with the whole arrangement that I replaced it all with a vernier locking cable. Problem solved. Also: most people don't know how to start it now.
 
The following users liked this post:
Mr Bird (01-22-2018)
  #5  
Old 01-22-2018, 07:47 AM
turbo2332's Avatar
Diesel Bomber
Join Date: Jun 2011
Location: Indiana
Posts: 2,171
Received 104 Likes on 101 Posts
Default

little blue wire, driver side battery. make sure that connection isn't corroded.
 
The following users liked this post:
Mr Bird (01-22-2018)
  #6  
Old 03-29-2018, 08:20 AM
windage's Avatar
Diesel Fan
Join Date: May 2015
Location: Vanceburg, KY
Posts: 20
Received 0 Likes on 0 Posts
Default

I did the same..took a little tinkering to set up, but works flawless...and like you said, if you leave the handle out..it's a no start!
 