Ford Powerstroke 99-03 7.3L Discussion of 99-03 7.3 Liter Ford Powerstroke Turbo Diesels

7.3 no start, unplug icp then ran, then no start

Thread Tools
 
Search this Thread
 
  #1  
Old 03-23-2013, 09:27 PM
Sunrise Gardens's Avatar
Diesel Fan
Thread Starter
Join Date: Mar 2013
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
Default 7.3 no start, unplug icp then ran, then no start

So........ 2002 7.3 Powerstroke, stock work truck. 244k miles. New fuel pump, fuel filter, cps sensor.

It died on me this morning a block from my house, pulled it home, checked HPOP level it was pretty empty, filled it up, still no start.

I unplugged the ICP sensor, it started right up, went for test drive, she ran awesome, then a mile away she died again. Towed it back again, I checked the level in the HPOP it was down about 1.5 to 2 inches again.

Does this mean that the IPR is bad also? Any help would be greatly appreciated.

Thank you in advance.

Adam
Reply With Quote
 
  #2  
Old 03-23-2013, 11:46 PM
strokin7.3:)'s Avatar
Diesel Fan
Join Date: Mar 2013
Location: Alabama
Posts: 34
Likes: 0
Received 0 Likes on 0 Posts
Default

My 99 done the same thing and i replaced the icp and it runs great now but as far as the hpop level i can't help you there.
 
  #3  
Old 03-24-2013, 07:25 AM
Sunrise Gardens's Avatar
Diesel Fan
Thread Starter
Join Date: Mar 2013
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
Default

Originally Posted by strokin7.3:)
My 99 done the same thing and i replaced the icp and it runs great now but as far as the hpop level i can't help you there.

So, you disconnected the icp and it ran for awhile, then died. After you replaced the icp it was fine?

Thanks
 
  #4  
Old 03-24-2013, 08:11 AM
strokin7.3:)'s Avatar
Diesel Fan
Join Date: Mar 2013
Location: Alabama
Posts: 34
Likes: 0
Received 0 Likes on 0 Posts
Default

Correct. one way to tell if it is bad is to see if oil is seaping through the plug. Also the icp should come with a new harness be sure to replace the harness and the icp.
 
  #5  
Old 03-24-2013, 08:46 AM
Sunrise Gardens's Avatar
Diesel Fan
Thread Starter
Join Date: Mar 2013
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
Default

There is a lot of oil coming out of the icp connection, so I am guessing that it is toast.

I am going to top off the hpop again, and replace the Icp tomorrow and see what happens.

Thanks again.
 
  #6  
Old 03-24-2013, 08:49 AM
strokin7.3:)'s Avatar
Diesel Fan
Join Date: Mar 2013
Location: Alabama
Posts: 34
Likes: 0
Received 0 Likes on 0 Posts
Default

Not a problem. people help me out a lot on here. just doing the same.
 
  #7  
Old 04-02-2013, 05:43 PM
Sunrise Gardens's Avatar
Diesel Fan
Thread Starter
Join Date: Mar 2013
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
Default

I replaced the icp - didn't start. Just replaced the IPR - didn't start. Now what?

I just stuck a ton of money into this thing and need it for work this spring, please help!
 
  #8  
Old 04-30-2013, 09:28 PM
Sunrise Gardens's Avatar
Diesel Fan
Thread Starter
Join Date: Mar 2013
Posts: 12
Likes: 0
Received 0 Likes on 0 Posts
Default

Solution: I had bad injectors. Sent injectors to Jim at Rosewood Diesel and had premium stock rebuild, now the truck purrs like a kitten, a big kitten. Thanks for the help everyone.

Adam
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Excursion73
Ford Powerstroke 99-03 7.3L
2
10-27-2015 05:21 PM
Bigredpowerstroke
Ford Powerstroke 94-98 7.3L
2
08-14-2015 10:31 AM
bajahigh
Ford Powerstroke 03-07 6.0L
1
12-09-2014 09:23 PM
custom7.3
Ford 83-94 6.9 and 7.3L General
1
11-23-2014 10:44 PM
SHIFTNGEARS
Ford Powerstroke 94-98 7.3L
1
10-30-2014 05:40 PM



Quick Reply: 7.3 no start, unplug icp then ran, then no start