Diesel In Distress - Support Ticket Need Help ? Broke Down Or in Urgent Need Of Assistance Post Here , Thread Will Be Priority and You have the ability to close your own thread when its fixed . If You Do Not Reply in 10 Days your thread will be closed as we will assume its fixed , You can Reopen YOUR Discussion Topic if you wish .

1998.5 cummins no start

Thread Tools
 
Search this Thread
 
  #1  
Old 12-15-2013, 01:57 PM
tune's Avatar
Newbie
Thread Starter
Join Date: Dec 2013
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Default 1998.5 cummins no start

I hope this does not show up twice. If so sorry.
I have a 1998.5 Dodge Cummins 24v extended cab long box. I use the truck to go get parts, pick up mowers, go to the store, and pull my car trailer with skid-steer on it. No extreme off-roading. The lift pump is located on the engine above the starter.
Last week on 12-8-13 I was bring my truck into the shop to put in a posi-lock cable system in the front diff. My truck stated to gel-up on the way into my shop, but it idled in. My shop is heat to about 65-70 degrease, it has been in there now for a week. I put the posi-lock in. Then went to change the fuel filter as I do about this time every year. I put the new filter in, filled the filter with #1. Bump the starter to have the lift pump kick in to help prime it. It ran for 1 second and quite, did not run for 20 seconds like it use to. I bought a new lift pump, tested it before putting it in and it also runs for only a second then stops. I have checked the wires going to the pump. When I hit the starter there is almost 11 volts, when the key is in the run position and the pump should be still running it drops to 8.66 volts. I have looked at the wires were I had to drill holes for the posi-lock and I did not hit any wires. It also has a edge d-541 programmer in it.
Thank you for you time.
Mark
 
  #2  
Old 12-18-2013, 10:00 PM
six speed's Avatar
Diesel Enthusiast
Join Date: Oct 2013
Location: Oklahoma
Posts: 238
Received 4 Likes on 4 Posts
Default

i'm not familiar with that programmer, but set it to stock and unhook the programmer. See if this makes any difference. Check your connections also as you might not be getting a good connection.could the other pump have pushed gelled fuel up towards the injector pump and now the lift pump is just pushing against it so it builds pressure and shuts itself off?
 
  #3  
Old 12-18-2013, 10:31 PM
tune's Avatar
Newbie
Thread Starter
Join Date: Dec 2013
Posts: 2
Likes: 0
Received 0 Likes on 0 Posts
Default

Thanks for the reply. I have checked power and all grounds, also took programmer out. It has sat inside a heated shop for over a week, so there should no longer be and geld fuel. Also I have take the lines lose from the lift pump so it can not build pressure. Know tonight (12-18-13), I disconnected the battery's to see if it would clear anything. Hocked them up, bumped started it, and the pump ran a cycled like it should. So I hocked everything up bump started it to prime the system and know the pump will not shut off. Unplugged the pump so it would not drain my battery's. I am thinking It might be the computer?
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Rusher48
24 Valve 2nd Gen Dodge Cummins 98.5-02
1
07-02-2020 08:39 AM
mcclusk
24 Valve 2nd Gen Dodge Cummins 98.5-02
3
02-21-2015 09:50 PM
Rusher48
Diesel In Distress - Support Ticket
7
02-20-2015 05:19 PM
rschriek
24 Valve 2nd Gen Dodge Cummins 98.5-02
2
01-26-2015 07:30 AM
Downd19
24 Valve 2nd Gen Dodge Cummins 98.5-02
3
12-30-2014 02:49 PM



Quick Reply: 1998.5 cummins no start



All times are GMT -5. The time now is 07:36 PM.