Old 05-31-2011, 06:33 PM
dolla_hite's Avatar
Diesel Enthusiast
Thread Starter
Join Date: Jan 2010
Location: central tx
Posts: 184
Likes: 0
Received 4 Likes on 4 Posts
Question need help please

so truck fell flat on its face when i was leaving work to go to lunch. just went a looked at codes and these are the ones that showed up.
P0216 Injection Timing Control Circuit Malfunction
P1693 Turbo Charge Control Circuit Malfunction
P1694 Turbo Charge Relief Circuit Malfunction
im going to go double check on the codes just to make sure. thanks for any help yall can give me
 
  #2  
Old 05-31-2011, 07:33 PM
outlaw1_gt's Avatar
Diesel Enthusiast
Join Date: Jul 2008
Location: Shippensburg, PA
Posts: 433
Received 18 Likes on 18 Posts
Default

Have you been having any hard starts or any other issues lately?
 
  #3  
Old 05-31-2011, 07:35 PM
dolla_hite's Avatar
Diesel Enthusiast
Thread Starter
Join Date: Jan 2010
Location: central tx
Posts: 184
Likes: 0
Received 4 Likes on 4 Posts
Default

no. went and got my new truck with it on saturday and didnt miss a lick
 
  #4  
Old 05-31-2011, 07:38 PM
turbo20psi's Avatar
Diesel Bomber
iTrader: (1)
Join Date: Mar 2009
Location: MD,NC
Posts: 3,228
Received 180 Likes on 149 Posts
Default

I would check your fuel pump relay,its under the hood driver side.
 
  #5  
Old 05-31-2011, 07:45 PM
outlaw1_gt's Avatar
Diesel Enthusiast
Join Date: Jul 2008
Location: Shippensburg, PA
Posts: 433
Received 18 Likes on 18 Posts
Default

do you have a stock lift pump or aftermarket like an airdog or fass?
 
  #6  
Old 05-31-2011, 07:46 PM
dolla_hite's Avatar
Diesel Enthusiast
Thread Starter
Join Date: Jan 2010
Location: central tx
Posts: 184
Likes: 0
Received 4 Likes on 4 Posts
Default

if it was a fuel pump relay it wouldnt run right? cause it runs fine just has no power

---AutoMerged DoublePost---

stock but its putting out good pressure
 

Last edited by dolla_hite; 05-31-2011 at 07:46 PM. Reason: Automerged Doublepost
  #7  
Old 06-01-2011, 02:03 AM
banditsdiesel's Avatar
Diesel Enthusiast
Join Date: Dec 2010
Location: chatsvegas, georgia
Posts: 271
Received 17 Likes on 16 Posts
Default

the 0216 is a timing malfunction code that is very general. it could be a large mixture of air in the fuel or could be the pump failing. also it could be something damaged in the pump, mine was throwing this code and we pulled the pump down to a broken delivery valve. the 1693 is a companion code from the jtec module. this is a code that basicaly says there is a code set and im not sure on the 1694 off the top of my head. it sounds like the pump could be failing to me...
 
  #8  
Old 06-01-2011, 02:33 AM
biged681985's Avatar
BOMBARDIER

Join Date: May 2008
Location: Yellville, Arkansas
Posts: 5,567
Received 338 Likes on 289 Posts
Default

time for a new VP44 and lift pump. every time i have seen the p0216 its been bad. the p0216 is considered the death code. imo, i would put an airdog on the truck when you replace the IP to make sure the vp44 always has a good supply of fuel. me or any of the other sponsors here on db can get you a IP and a LP and a lot of the time when you buy them both you can get a lil better deal
 
  #9  
Old 06-01-2011, 06:59 PM
dolla_hite's Avatar
Diesel Enthusiast
Thread Starter
Join Date: Jan 2010
Location: central tx
Posts: 184
Likes: 0
Received 4 Likes on 4 Posts
Default

but if its the ip would it still run?

---AutoMerged DoublePost---

anybody else have any input for me?
 

Last edited by dolla_hite; 06-01-2011 at 06:59 PM. Reason: Automerged Doublepost
  #10  
Old 06-02-2011, 09:01 AM
ntallent's Avatar
Diesel Fan
Join Date: Feb 2011
Location: lampasas
Posts: 47
Likes: 0
Received 2 Likes on 2 Posts
Default

yes it will still run it just wont have the power it should because its not supplying enough fuel to the injectors
 