12 Valve 2nd Gen Dodge Cummins 94-98 Discussion of 12 Valve 5.9 Liter Dodge Cummins Diesels with P7100 Injection Pumps

truck will not stay running after big line kit

Thread Tools
 
Search this Thread
 
  #11  
Old 04-03-2014, 04:33 PM
ebarresi5894's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2011
Location: Rehoboth, MA
Posts: 525
Received 12 Likes on 12 Posts
Default

Already deleted it it's almost like it's choppy for the first 10 seconds then smooth out and runs perfectly fine
 
  #12  
Old 04-03-2014, 06:33 PM
Diesel Duo's Avatar
Diesel Fan
Join Date: Oct 2013
Location: Nebraska
Posts: 38
Received 1 Like on 1 Post
Default

Is the fuel shut off solenoid getting bound up maybe?
Or a bad connection @ shut off relay?
Possibles...
Hope it helps.
DD
 
  #13  
Old 04-03-2014, 07:08 PM
ebarresi5894's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2011
Location: Rehoboth, MA
Posts: 525
Received 12 Likes on 12 Posts
Default

Ill look into thay thanks
 
  #14  
Old 04-03-2014, 08:34 PM
4x4manonbroke's Avatar
Diesel Bomber
Join Date: Jun 2010
Location: Tacoma
Posts: 3,202
Received 142 Likes on 136 Posts
Default

sounds like air intrusion as my truck does that same thing every morning ... what did you set your fuel pressure at ....


Also .. might think about a check valve at the return line so it dosent drain whats in the return line and that could be your studder also ...
 
  #15  
Old 04-03-2014, 09:04 PM
turbo2332's Avatar
Diesel Bomber
Join Date: Jun 2011
Location: Indiana
Posts: 2,171
Received 104 Likes on 101 Posts
Default

does it smoke? -white-? for these few seconds

---AutoMerged DoublePost---

OE mechanical lift pump? drain back?
 

Last edited by turbo2332; 04-03-2014 at 09:04 PM. Reason: Automerged Doublepost
  #16  
Old 04-04-2014, 04:28 AM
ebarresi5894's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2011
Location: Rehoboth, MA
Posts: 525
Received 12 Likes on 12 Posts
Default

I bought a ofv020 so i would imagine its set at 30. Where could i get a check valve?

Yes oem pump. Whay do you mean by drawback?
 
  #17  
Old 04-04-2014, 05:41 AM
turbo2332's Avatar
Diesel Bomber
Join Date: Jun 2011
Location: Indiana
Posts: 2,171
Received 104 Likes on 101 Posts
Default

chances are the weight of the fuel in the 1/2'' line is partially draining back to the tank after you shut the truck off. the problem is compounded because your stock lift pump doesnt move nearly as much fuel as an electric ans the truck has to actually be running before its moving fuel. my truck used to start immediatly hen it had stock fuel lines. now even with the electric pump it is hesitant to start unless i let the electric pump purge for a few seconds before i crank. i bet because you cant purge the lines before you crank is why you are seeing a a hard start.
 
  #18  
Old 04-04-2014, 01:04 PM
ebarresi5894's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2011
Location: Rehoboth, MA
Posts: 525
Received 12 Likes on 12 Posts
Default

Anyway to solve that? Maybe a pump before the stock one?
 
  #19  
Old 04-04-2014, 03:44 PM
4x4manonbroke's Avatar
Diesel Bomber
Join Date: Jun 2010
Location: Tacoma
Posts: 3,202
Received 142 Likes on 136 Posts
Default

Sorry it was supposed to read drain back ... Install one way check valve I return line and problem solved ....

no need for a electric pump unless you intend on doing some real power upgrades or something like that....
 
  #20  
Old 04-06-2014, 09:44 AM
ebarresi5894's Avatar
Diesel Wrench
Thread Starter
Join Date: May 2011
Location: Rehoboth, MA
Posts: 525
Received 12 Likes on 12 Posts
Default

Sounds good ill get a check valve today to put on the return line
 


Quick Reply: truck will not stay running after big line kit