I got a 96 dodge 2500 with the 12v. The tach, spedo isn't working. Alternator isn't charging. No wait to start or any other lights come on the dash. No check engine light.

I have a electric fan wired straight to the batteries on the high side and the low side is controlled by a Haydens controller. I turned on the high side to cool the engine down quicker and I had it on for about 5 minutes then when I hopped back into the truck the GEN light was on and when I turned the high side off the light went off but the alternator wasn't charging anymore and the trans wouldn't shift out of 1st gear. Lost the spedo and tach at the same time. I checked all my fuses and they are all good.

What does this sound like I need to know ASAP. Is this a bad alternator or bad CSS or something else?

My thinking is I overloaded the alternator running the electric fan on high for so long because that was the most recent thing I did before this happened. Alternator is still covered under warrantee.
 
  #2  
Old 08-13-2013, 07:39 PM
4x4manonbroke's Avatar
Diesel Bomber
Join Date: Jun 2010
Location: Tacoma
Posts: 3,202
Received 142 Likes on 136 Posts
Default

check your main fuse or see if there is a fusable ling @ alternator or something ...
 
  #3  
Old 08-13-2013, 08:17 PM
96cummins12v.'s Avatar
Diesel Fan
Thread Starter
Join Date: Aug 2012
Posts: 29
Likes: 0
Received 0 Likes on 0 Posts
Default

All fuses are good. I just pulled the ecm off the truck and started the truck and everything is the exact same as if it were still plugged it. Havent had a problem till after I ran the electric fan on high for a few minutes and im pretty sure the fan pulls 30 amp which may overload the ecm if the regulator is internal. Is my thinking correct and without me really knowing I fried my own ecm
 
  #4  
Old 08-14-2013, 11:22 AM
94 12valve's Avatar
Diesel Bomber
Join Date: Jan 2009
Location: Pylesville, Maryland
Posts: 3,504
Received 157 Likes on 142 Posts
Default

if you wired it right to the bat I don't see how the fan could have hurt anyhing. I have a set of dual elec fans wired right into the bat on my truck and have never had that issue before.

Try unhooking the tach sensor and see if that fixes your issue. If it shorts internally it will cause the issues your talking about.
 
  #5  
Old 08-14-2013, 05:17 PM
96cummins12v.'s Avatar
Diesel Fan
Thread Starter
Join Date: Aug 2012
Posts: 29
Likes: 0
Received 0 Likes on 0 Posts
Default

Would a bad alternator cause this problem too?

---AutoMerged DoublePost---

So I looked over the truck and found some what of I though happened but don know the full extent. The power going to my switch to run the high side of my fan got hot and melted. It melted into the ground wires for my lights on my gauges, ignition feed to the Hayden controller. Ground wire to some of my lights and two wires in the harness underneath the dash. I'm gonna repair the damage and give her a shot. I earlier pulled all the wires apart and disconnected the white wire from the battery and nothing changed?????
 

Last edited by 96cummins12v.; 08-14-2013 at 05:17 PM. Reason: Automerged Doublepost
  #6  
Old 08-15-2013, 06:46 PM
tiremann9669's Avatar
Diesel Bomber
Join Date: Mar 2010
Location: Dansville NY
Posts: 4,233
Received 434 Likes on 356 Posts
Default

Crank sensor
 
  #7  
Old 08-15-2013, 08:19 PM
4x4manonbroke's Avatar
Diesel Bomber
Join Date: Jun 2010
Location: Tacoma
Posts: 3,202
Received 142 Likes on 136 Posts
Default

o man magic blue smoke is a real bit$% to get back in the wire ..... gonna be spendy
 
  #8  
Old 08-19-2013, 07:53 PM
96cummins12v.'s Avatar
Diesel Fan
Thread Starter
Join Date: Aug 2012
Posts: 29
Likes: 0
Received 0 Likes on 0 Posts
Default

I replaced the crank sensor and nothing. Im going over the wiring harness now and seeing a few burnt wires and some are burnt back enough where I do not know where they go to.......
 
  #9  
Old 08-20-2013, 02:49 PM
4x4manonbroke's Avatar
Diesel Bomber
Join Date: Jun 2010
Location: Tacoma
Posts: 3,202
Received 142 Likes on 136 Posts
Default

That's gonna be a problem ..... ur gonna have to trace each wire individually to get it done ...... I had to do this before .... real pain in the butt
 
  #10  
Old 08-21-2013, 10:07 AM
96cummins12v.'s Avatar
Diesel Fan
Thread Starter
Join Date: Aug 2012
Posts: 29
Likes: 0
Received 0 Likes on 0 Posts
Default

So the crank position wasnt getting a ground or power. Finally got power to it and got connection to the ground but guess what. Still nothing I ordered a new pcm yesterday so it will be here Saturday but unfortunatly its one day late of being able to make the local pulls at the county fair. Oh well but still I'm worried the new pcm still wont fix it.......
 